LIFESPAN
Cresto products consisting entirely of non-textile components
do not have a fixed lifespan. Cresto products that consist of
textile components of any kind have a maximum lifespan of
10 years from the date of manufacture. Maximum product
lifespan is not guaranteed, and is subject to the proper
use, storage, maintenance, and inspection conditions
as detailed in the applicable product instruction manual.
Products exposed to hazardous environments, including,
but not limited to, demolition, steel construction, high heat,
UV radiation, chemicals, or high salinity may have a reduced
lifespan. Product suitability for use can only be determined
by pre-use inspections, scheduled maintenance, thorough
inspection conducted by a Competent Person (CP), and
other conditions as specified by the risk assessment and the
product instruction manual.
QUALITY
All Cresto products are manufactured under ISO 9001:2015
and to the highest standards.
MAINTENANCE, CLEANING, AND
STORAGE
Maintenance and cleaning after use is important for
maintaining the safety and longevity of equipment. Remove
all dirt, corrosives, and contaminants from equipment before
and after each use. Textiles must only be cleaned with plain
water (not exceeding 50°C), or if plain water is not sufficient,
with mild soap/water solution. Rinse thoroughly and leave
to dry naturally out of direct sunlight and away from direct
heat sources. Never store when equipment is wet. Never
clean equipment with corrosive substances. When not in
use or during transport, store equipment where it will not be
affected by heat, light, excessive moisture, chemicals, or other
degrading elements.

INSPECTION

Prior to EACH use, inspect the equipment and connection
points for signs of deficiencies, including, but not limited to,
corrosion, deformation, pits, burrs, rough surfaces, sharp
edges, cracking, rust, paint build-up, excessive heating,
alteration, broken stitching, fraying, missing or illegible
labels, and additionally all Check points in the pre-use
inspection criteria. IMMEDIATELY remove equipment
from service if defects or damage are found, or if exposed
to forces of fall arrest. Ensure that applicable work area is
free of all damage, including, but not limited to, debris, rot,
rust, decay, cracking, and hazardous materials.
See Inspection Log on page 12
Workplace conditions, including, but not limited to, flame/
high heat, corrosive chemicals, electrical shock, sharp
objects or edges, machinery, abrasive or uneven surfaces,
UV exposure, and severe or prolonged weather conditions,
must be assessed by a CP before fall protection equipment
is selected. The presence of any/all of these conditions may
have negative effects on product performance or service
lifetime. Always inspect the entirety of the product.
Pre-use Inspection:
ƒ Device
Housing and housing connection point must be
intact and shows no signs of deficiencies such as
those listed previously. Ensure all housing screws
are present.
ƒ Lifeline
Inspect the entire length of lifeline for cuts abrasions
and wear marks. Ensure that the lifeline is free from
cuts, abrasion, excessive heating/soiling, wear
marks, broken stitching, fraying, bird-caging, and
wear point reinforcement (if applicable) is present.
ƒ Connection Points
Check that all connectors automatically close and
lock securely. All connectors must be free from
deficiencies such as those listed previously. Check
the fall indicator on the connector (if fitted) has not
been deployed.