26 | English
– Remove the cap nut (3), the air cap (2), the nozzle cap
used (10)/(11)/(12) and the suction tube (17) with the
container seal (16).
– Clean all paint-carrying parts in a bucket with warm water
using the cleaning brush (28) or with a commercially
available washing-up brush. Also clean the paint
channel (19) of the spray gun (1).
– Check that the suction tube (17) and the container
seal (16) are free of spray material and undamaged.
– Clean the ventilation hole (18) using the cleaning
brush (28).
– If required, clean the filling sieve (13) thoroughly with
warm water.
– Clean the outside of the container (7) and the spray
gun (1)with a damp cloth.
– Allow all components to dry thoroughly before assem-
bling them.
– Reassemble the fine-spray system in reverse order.
Slide the container seal (16) upwards again into the
groove of the suction tube (17).
Ensure that the container seal is positioned precisely all
around in the suction tube groove in order to seal the
spray gun correctly.
Make sure that you slide the suction tube (17) all the way
back onto the paint channel (19).
Cleaning After Using Solvent-Based Paints (see figure M)
Always clean the spray gun and the container for the spray
material with the respective diluting agent for the spray ma-
terial being used.
Never clean the nozzle and air holes in the spray gun with
pointed objects.
Wear suitable gloves during cleaning work involving solvents
and solvent-based paints.
– Switch off the base unit (22) and remove the air
hose (20) from the spray gun (1).
– Clean the base unit if necessary with a cloth moistened
with diluting agent and then remove the base unit (22)
and the air hose (20) from the immediate cleaning envir-
onment.
– Remove the container (7) from the spray gun (1).
Hold the container (7) underneath the suction tube (17)
and pull the trigger switch (5) on the spray gun so that the
spray material can flow back into the container.
– Empty the container (7).
The spray material can be stored in an airtight, sealed
paint container for other applications. Use the spare
container (8) with cover or the original spray material
container, for example, for this purpose.
– Clean the container (7).
– Remove the suction tube (17) with the container
seal (16) and rinse it thoroughly.
Reattach the suction tube (17) with the container
seal (16) to the spray gun.
– Fill the container (7) halfway with solvent and fit it to the
spray gun (1)again.
1 609 92A 7VA | (30.05.2022)
– Shake the spray gun several times.
Make sure that you do not spray the diluting agent. There
is a risk of explosion.
– Remove the container (7) from the spray gun (1)and
empty it completely into a sealable material tin.
– Remove the cap nut (3), the air cap (2), the nozzle cap
used (10)/(11)/(12) and the suction tube (17) with the
container seal (16).
– Clean all paint-carrying parts in a bucket with diluting
agent using the cleaning brush (28) or with a commer-
cially available washing-up brush. Also clean the paint
channel (19) of the spray gun (1).
– Check that the suction tube (17) and the container
seal (16) are free of spray material and undamaged.
If required, clean the container seal (16) again with dilut-
ing agent.
– Clean the ventilation hole (18) using the cleaning
brush (28).
– If required, clean the filling sieve (13) thoroughly with di-
luting agent.
– Clean the outside of the container (7) and the spray
gun (1)with a cloth moistened in diluting agent.
– Allow all components to dry thoroughly before assem-
bling them.
– Reassemble the fine-spray system in reverse order.
Slide the container seal (16) upwards again into the
groove of the suction tube (17).
Ensure that the container seal is positioned precisely all
around in the suction tube groove in order to seal the
spray gun correctly.
Make sure that you slide the suction tube (17) all the way
back onto the paint channel (19).
Cleaning the air filter (see figure N)
The air filter (30) must be cleaned occasionally. The air filter
must be replaced if it is heavily contaminated.
– Open the air filter cover (29).
– Remove the air filter (30).
– Light contamination:
Knock on the air filter (30).
or
Heavy contamination:
Clean the air filter (30) under running water and sub-
sequently leave it to dry thoroughly, in order to prevent
mould from forming.
or
Replace the air filter (30).
– Reinsert the air filter.
– Close the air filter cover (29) again.
Never use the fine-spray system without air filter. Dirt
u
particles may get into the motor compartment and dam-
age it.
Material Disposal
Contaminated diluting agent, remnants of spray material
and, if applicable, remnants of diluting agent must be dis-
posed of properly and in an environmentally friendly man-
Bosch Power Tools