Running indicator (green)
The running indicator lights up when generating set
starts and has normal output.
Overload indicator (red)
When the overload indicator is on, it indicates that
the generating set is overload and it may cause
overheat of frequency converter, or increase of AC
voltage. And then the AC protector works. It will
stop the output of generating set to protect the
electric equipment and the generating set itself. At
this time, the running indicator (green) is off and the
overload indicator (red) is on, but the engine is still
in running state.
When the generating set has no output and the
overload indicator is on, please take the following
steps:
1.
Lower the total power of the connected electric
devices to the rated output range of generating
set.
2.
Check the air intake for impurities and check
the control parts for abnormal situation. Handle
immediately if necessary.
3.
Press the reset button.
Oil alarm lamp (yellow)
When the oil level drops below the lower limit, the
oil protection system will stop the engine
automatically and oil alarming lamp will blink by
pulling the recoil starter. The engine will not run
until the oil has been filled to the proper level.
Note: If engine flames out or fails to start, turn the
two-in-one switch to "RUN" position and then pull
the recoil starter. If the oil alarming lamp lights up,
it shows lack of oil. Please add appropriate oil and
restart the engine.