Herunterladen Inhalt Inhalt Diese Seite drucken

Corrective Action - Livington INSTACHILL Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für INSTACHILL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Troubleshooting:
Problem
The evaporative air cooler
does not work and does not
respond to the buttons being
pressed.
There is no air flow from the unit,
even though the machine is in
operation.
The pump works, but the
appliance does not cool.
"Cool" button flashes
The pump works, but does not
circulate water, or the special
filters contain too little water.
Water spurts out of the device.
There is an unpleasant odour.
White sediments are visible in
the water tank.
M21360_M27532_Livington InstaChill_Manual_20220215_MM.indd 9
M21360_M27532_Livington InstaChill_Manual_20220215_MM.indd 9
Possible Cause
Power failure or faulty power
connection.
The remote control batteries are
empty.
The remote control or the control
panel is damaged.
The remote control.
The motor is damaged.
The thermal protection in the
motor has been triggered.
The cooling function (water
being pumped to the filters) is
not switched on.
The special filter is clogged or
has become dirty.
The special filter is dry or does
not contain enough water.
The relative humidity is
excessively high.
There is not enough water in
the tank.
There is not enough water in
the tank.
The upper water distribution tray
has become clogged.
There is not enough water in
the tank.
The special filter or the rear cover
(J) is not in the right position.
The upper water distribution tray
has become clogged.
The water tank or the special
filter is dirty.
The water is too hard.

Corrective Action

Measure the input voltage and
connect the device to a dedicated
power source.
Change the batteries.
Please contact our customer
services.
The remote control must be
pointed directly at the appliance.
Please contact our customer
services.
Turn off the appliance until the
motor has cooled down.
The cooling symbol must be
pressed again each time after
switching on.
Clean or replace the special filter.
Check the upper water
distribution tray, and determine if
there is a blockage.
The cooling function is
deactivated - please activate
When the evaporative air cooler
is used for an extended period
of time, the humidity in the room
can become very high, so the
temperature can not be reduced
to as great an extent. Turn the
cooling mode to a lower level or
deactivate it until the humidity
has decreased.
Fill the tank up to at least the
minimum mark (approx. 2.5
litres).
Fill the tank up to at least the
minimum mark (approx. 2.5
litres).
Clean the upper water
distribution tray.
Fill the tank up to at least the
minimum mark (approx. 2.5
litres).
Position the special filter or the
rear cover (J) correctly.
Clean the upper water
distribution tray.
Clean the water tank and the
special filter.
Drain the water tank, and clean
or de-scale the special filters and
tank more frequently.
9
Remarks
It is recommended to use a
voltmeter to determine the
precise voltage.
Note: The colder the water, the
better the cooling effect.
Note: The colder the water, the
better the cooling effect.
Note: The colder the water, the
better the cooling effect.
In areas with hard water, use
distilled water in the future.
15.02.22 07:25
15.02.22 07:25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis