Binding the Wireless thermostat and RF Receiver
The maximum temperature limit is now displayed. The setting
can be changed using the setting ring. There is no need to
confirm the value.
While this setting is flashing, touch the left or right touch zone
briefly to display the minimum temperature limit. This can also
be changed using the setting ring.
The thermostat cannot be used to turn the system on and off
unless the limit for minimum temperature is set to a value lower
than 11ºC (ex: 5ºC).
The installation menu is closed automatically after 10 seconds of
inactivity.

2.2.7 Reset to default

Rotate the setting ring fully to the left until the minimum
temperature is shown.
When the value starts flashing, touch and hold on left or right
touch zones for approximately 10 s. The maximum temperature
limit is now displayed flashing, touch the left or right touch zone
briefly.
When the minimum temperature limit is flashing, touch again the
left touch zone.
The symbol
appears on the screen, touch and hold during
10 s the left touch zone and the device resets the default settings.

2.2.8 Replacement of the batteries

1 Pull to remove the dial ring.
2 Detach the thermostat from the base.
3 Replace the batteries as shown at the picture.
4 Attach the thermostat to the base.
5 Place the dial ring.
7
PMML0502 rev.1 - 01/2021
3 BINDING THE WIRELESS
THERMOSTAT AND RF RECEIVER
By default the thermostat is already linked to the RF receiver.
For these reason there is no need to perform binding procedure
in case it is only required one wireless thermostat at the
installation.
The binding operation described below is required if:
Any of the system components (Room Thermostat or
RF Receiver) are replaced. Go to step 1.
The RF Receiver has incorrect or no binding data stored
(e.g. when pre-bound system pack components have been
mismatched). Go to step 1.
When adding a second wireless thermostat. Go to step 2.
?
N O T E
During the binding procedure keep approximately 1m distance between
the Room Thermostat and the RF Receiver.
1 Hold button on RF Receiver for 15 seconds in order to
remove all the configurations. At the end of the procedure,
LED will flash 0.5 seconds ON and 4 seconds OFF.
2 Hold button on RF Receiver for 5 seconds. Led will flash for
1 seconds ON and 1 second OFF.
3 Bind the thermostat. Touch and hold on the right touch zone
for approximately 10 seconds.
4 The screen for binding the RF Receiver is now displayed.
5 Briefly touch the right touch zone to send the binding signal,
at which point the symbol
Press here
LED
10s
will flash several times.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

20803

Inhaltsverzeichnis