Message or code
Substrate may be detached from
the rear spindle or slippage
detected. Substrate will be
unloaded.
System error
Very low cleaner roll
10.04.XX:YY
10.06.09:40
10.06.09:41
22.02.0X:06
22.02.0X:07
46.05.0X:06
47.01.06:52
51.01.00:92
58.02.00:02
8
Recommendation
See the user guide.
The printer has a system error. In the alert window, you should see the
numerical code of the system error.
Be ready to replace the printhead cleaning roll very soon.
Problem with e-cabinet fuses. The message in the IPS will indicate which
fuse is causing the issue in order to replace it. Diagnostic e-cabinet state
can be used to confirm that the issue is solved.
The emergency stops and/or safety relay have been activated. Check that
the emergency stops are not activated. If the problem persists, run a
diagnostic to identify the issue.
The emergency stops and/or safety relay have been activated. Check that
the emergency stops are not activated in the printer nor in the input and
output units. If the problem persists, run a diagnostic to identify the issue.
Intermediate tank broken bag detected. Proceed with the intermediate
tank maintenance procedure (see the Print Care wizard: Replace an
intermediate tank).
Intermediate tank end of life reached. Proceed with the intermediate tank
maintenance procedure (see the Print Care wizard: Replace an
intermediate tank).
Primer X leakage. Reset primer latch and/or check o-rings. If problem
persists, call your support representative.
Printhead cleaning roll pinch unlocked. Ensure that the pinch system of the
printhead cleaning roll assembly is properly closed, and that there is no
slippage between the core of the printhead cleaning roller and its motor.
The main window is open. Close the window to continue printing. If the
problem persists, run a diagnostic to identify the issue.
Spectrophotometer shutter door open/close check fail. Run the Color
sensor check diagnostic and check at the IDS side of the printer that the
shutter is opening and closing properly. If the door is opening and closing
but the printer does not detect it, clean the spectrophotometer. If the door
is not opening and closing, install a new shutter mechanism (see Replace
the spectrophotometer shutter in the user guide:
StitchS1000126in/manuals).