Message or code
58.03.00:84
86.01.00:01
The above table includes the most significant numerical codes. If you receive an error code that is not in the table,
follow the instructions in the message.
Printer specifications (under RMN: BCLAA-1909)
Electrical specifications
Power (typical)
Frequency
3
Acoustic specifications
Declared noise emission levels: maximum A-weighted sound pressure levels at bystander position measured per ISO
11202.
Idle sound pressure level
Operating sound pressure level
Environmental specifications
Operating for optimal
print quality
Operating for standard
printing
ENWW
Recommendation
Spectrophotometer calibration failure. Run the Color sensor check
diagnostic. If there is an issue related to the spectrophotometer shutter,
replace it (see Replace the spectrophotometer shutter in the user guide:
http://www.hp.com/go/StitchS1000126in/manuals). Otherwise clean the
spectrophotometer. If the problem persists, call your support
representative.
Carriage movement failure. Ensure that maintenance routines are up to
date, then perform Reinitialize carriage from the Internal Print Server. Also
perform the carriage-rail cleaning process (see Clean the scan axis and
mechanical transmissions in the user guide:
StitchS1000126in/manuals).
AC voltage
Current max
Temperature range
20 to 25°C (68 to 77°F)
15 to 30°C (59 to 86°F)
http://www.hp.com/go/
6 kW
50 / 60 Hz
200–240 / 380–415 V
32 A / 23 A
52 dB (A)
64 dB (A)
Humidity range
30 to 60% relative
humidity
20 to 70% relative
humidity
Temperature gradient
10°C/h (18°F/h) or less
10°C/h (18°F/h) or less