Ferroli OMNIA S 3.2 Installations- Und Bedienungsanleitung Seite 118

Wandgehängte innengeräte für umkehrbare split-wärmepumpen mit dc-inverter-verdichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 330
Menu
Menu
Level 1
Level 2
3.1 Heat Mode
3.2 T_T4_Fresh_H
3.3 T4Hmax
3.4 T4Hmin
3.5 Dt1Sh
3.6 Reserved
3.7 T_Interval_H
3 Heat Mode
3.8 T1Seth1
For Serviceman
Setting
3.9 T1Seth2
3.10 T4H1
3.11 T4H2
3.12 Zone1 H-Emission
3.13 Zone2 H-Emission
3.14 T_Delay_Pump
5.1 Water Flow Temp.
5 Temp. Type
For Serviceman
5.2 Room Temp.
Setting
5.3 Double Zone
6 Room
For Serviceman
6.1Room Thermostat
Thermostat
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7 Other Heating
For Serviceman
Source
7.5 t_AHS_DELAY
7.6 T4_AHS_ON
7.7 IBH LOCATE
8.1 T1S H.A. H
8 Holiday
For Serviceman
Setting
8.2 T5S H.A. DHW
10 Restore
10, 1 Restore Factory
For Serviceman
Factory Settings
Settings
11.1 Test Run Enable
11.2 Trail run steps
For Serviceman
11 Test Run
11.3 Point Check
118
EN
Menu
Menu
Level 3
Level 4
Double zone
none / mode setting /one
zone / double zone
Pipe Loop=0; Buffer
Tank=1
3way-valve 1
3way-valve 2
PUMPS
PUMP
PUMPC
PUMPSOLAR
PUMPDHW
INNER BACKUP HEATER
TANK HEATER
3WAY-VALVE 3
Cod. 3541V941 - Rev. 04 - 05/2022
Description
Enables or disables the heating mode
The set point update time calculated by the
climatic curve for the heating mode
The maximum external air temperature to which
the heat pump can operate in heating mode
The minimum external air temperature to which
the heat pump can operate in heating mode
Hysteresis set point for restarting the heat pump
in heating mode
Reserved
Time between shut-down and start-up of the
compressor in heating mode
Set point 1 of climatic curve no. 9 for heating
mode.
Set point 2 of climatic curve no. 9 for heating
mode.
The external air temperature 1 of the climatic
curve no. 9 for the heating mode.
The external air temperature 2 of the climatic
curve no. 9 for the heating mode.
The type of zone 1 terminal for cooling mode:
FCU (fancoil): RAD. (Radiator): FLH (floor
heating)
The type of zone 2 terminal for cooling mode:
FCU (fancoil), RAD (radiator), FLH (floor heating)
Delay between pump activation and subsequent
compressor activation
Reserved
Reserved
Enables/disables control of 2 zones
Select the type of control on the thermostat digital
input (none, mode setting, one zone, double
zone)
The temperature difference between T1S and T1
for starting the back-up system electric heater.
Compressor operating time before the activation
of the back-up system electric heater
Maximum external air temperature below which
the back-up system electric heater can be
activated
The temperature difference between T1S and
T1 for switching on the additional heating source
(gas boiler)
Compressor operating time before activating the
additional heating source (gas boiler)
Maximum external air temperature below which
the additional heating source (gas boiler) can be
activated
Installation position of the back-up system
electric heater IBH
PIPE LOOP = 0 if the system electric heater is
installed in series with the heat pump;
BUFFER TANK = 1 if the system electric heater
is installed on the system tank
The target water output temperature for heating
the room in holiday mode
DHW water heater temperature set point in
holiday mode
Restore Factory Settings
TEST RUN ENABLE 0 = OFF 1 = ON - to enable
the menu "11.2 Trail run steps"
Point Check = to activate the menu "11.3 Point Check"
Air purge = ON - to activate the air bleed
Water pump = ON - to activate the water pump
Cooling = ON - to activate the cooling mode
Heating = ON -to activate the heating mode
Dhw = ON - to activate the DHW mode
TEST ON-OFF
Allows you to run a functional test on single loads, individually
forcing the activation and subsequent switching off.
Also allows you to temporarily force the system in specific
function modes for the test (air bleed, recirculation pump
running, etc.).
The switching on/off of each function is always done
manually.
It is only possible to enable/disable one function at a time; it is
not allowed at the same time.
If one function is active and you exit the Test Run menu while
it is active, the function will automatically switch off.
OMNIA S 3.2
Unit of
Lower
Upper
Remedy
measure-
limit
limit
ment
Yes
No
/
/
0.5
6
0.5
h
20
35
1
°C
-25
30
1
°C
2
20
1
°C
-
-
-
-
5
60
1
min
25
65
1
°C
25
65
1
°C
-25
35
1
°C
-25
35
1
°C
FCU/
FLH
/
/
RAD
FCU/
FLH
/
/
RAD
2.0
20.0
0.5
min
Yes
No
/
/
Yes
No
/
/
Yes
No
/
/
None / Mode Set / One Zone / Double Zone
2
10
1
°C
15
120
5
MIN
-15
10
1
°C
2
20
1
°C
5
120
5
MIN
-15
30
1
°C
0
1
0
/
20
25
1
°C
20
25
1
°C
Y
N
/
/
OFF
ON
/
/
Point Check / Air purge / Water pump / Cooling
/ Heating / Dhw
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
OFF
ON
/
/
Default
value
Yes
0.5
25
-15
5
-
10
35
28
-5
7
FCU/
RAD
FLH
2.0
Yes
No
No
None
5
30
-5
5
30
-5
0
25
25
N
OFF
Point
Check
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF