Herunterladen Diese Seite drucken

JSP JETSTREAM Bedienungsanleitung Seite 5

Betriebene filtervorrichtung mit einem helm oder einer haube, gerät der klasse th2

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
Spark Guard
The Spark Guard is included with the Jetstream™ TH2P filter (not suitable for fitting to the Jetstream™ TH2A2 or
TH2A2P filters or other types of JSP filters).
The Spark Guard is a simple push fit. Line up the finger recess on the Spark Guard with the finger recess on the filter
housing (see diagram 9, 10 and 11) and push into place. Ensure a positive click fit is heard.
Diagram 9:
FINGER RECESS
FINGER RECESS
When the Jetstream™ TH2P filter is exhausted simply pull off the Spark Guard.
Under normal circumstances the Spark Guard can be used up to 5 times. The
Spark Guard should be cleaned between each use. Use a cloth moistened in a
warm diluted mild detergent solution, the Spark Guard should be allowed to air
dry. Under no circumstances should you use any solvents or abrasive cleaners
be used. The unit must not be dried using hot air or radiant heat.
Starting the Blower-Unit
Activate the Power-Switch at the rear of the unit (See Diagram 12.) and wait to see that the buzzer turns off after about
10 seconds. If this does not occur, the unit may require recharging or a new filter fitting.
Checking the Airflow
With the Blower-Unit running, place the Flow-Test-Unit onto the Blower-Unit so that the sealing gasket is securely
gripping the 'chimney'. (See Diagrams 13 & 14.) Check that the indicator lever rises above the red fail and into green
pass sector. (See Diagram 15.)
Diagram 13:
FLOW TEST UNIT
FLOW TEST UNIT
GASKET
GASKET
Donning the Blower Unit
Place belt around waist and fasten snap fit buckle. To adjust fit of belt pull free end away from the Velcro fastening and
pull through buckle. The belt should be tightened/loosened so that the blower unit sits comfortably, usually at the small
of the back. The free end of the belt should be flattened against the Velcro fastening.
Diagram 10:
FINGER RECESS
FINGER RECESS
Diagram 14:
INDICATOR LEVEL
INDICATOR LEVEL
PASS
PASS
FAIL
FAIL
Diagram 11:
Diagram 12:
SWITCH
SWITCH
Diagram 15: