Herunterladen Diese Seite drucken

JSP JETSTREAM Bedienungsanleitung Seite 2

Betriebene filtervorrichtung mit einem helm oder einer haube, gerät der klasse th2

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
Important - Please read these instructions carefully before unpacking your Jetstream™ product.
Failure to comply with the instructions in this leaflet may void your warranty and adversely affect your health. If you
have any questions regarding the suitability of this product to your task, please contact an occupational hygienist or call
the manufacturers technical help line. Address and Telephone number information is printed at the back of this leaflet.
Unpacking - Your Jetstream™ Powered Respirator should include:
a) Blower Unit
b) Belt
c) Head Cape with Hose
d) Airflow Test Unit
e) Battery Charger
f) Instruction Leaflet
g) Filter (Type depends on model)
If any of the above components are not included in your kit, please contact the supplier immediately.
Approvals - Jetstream™ - Jetstream™ has been designed and manufactured to comply with EN12941: 1998 as a
TH2 device. BS4275 (Guide to implementing an effective respiratory protective device programme), which the user
is advised to read, defines an EN12941 TH2 device as offering an Assigned Protection Factor of 20. Jetstream™ can
only provide this level of protection when used with filters provided by the manufacturer marked "Jetstream™" and
"EN12941:1998 TH2". Jetstream™ is manufactured under a BS EN ISO 9001 Quality System.
Limitations To Use - This Respirator must be used strictly in accordance with this instruction leaflet and the
instructions supplied with corresponding head-units.
When the blower unit is switched off little or no respiratory protection is to be expected. When the blower unit is
switched off a rapid build up of carbon dioxide and depletion of oxygen within the head unit may occur.
DO NOT use Jetstream™ with the blower unit switched off.
DO NOT use Jetstream™ in an atmosphere that is immediately hazardous to user hygiene or health,
has oxygen content of less than 19.5% or contains unknown substances
DO NOT expose to flames and/or sparks.
DO NOT use Jetstream™ in an explosive atmosphere.
DO NOT use Jetstream™ in confined spaces or areas of poor ventilation.
DO NOT use Jetstream™ in high winds.
DO NOT alter or modify in any way.
DO NOT touch any of the moving parts.
DO NOT remove the Battery cover, this is for use by the Manufacturer only.
DO NOT allow water or other liquids to enter the Impeller Chamber / Volute or Battery Compartment.
There is a possibility that the hose to the head unit may become caught up in use.
The blower unit should be positioned on the person in such a way as to reduce this possibility.
Filters cannot be fitted directly to the head units and should not be adapted to do so.
Correct respiratory protection will not be provided if any parts of the equipment are modified.
At very high work rates the pressure in the device may become negative at peak inhalation flow.
Jetstream™ are for use only by competent, trained personnel.
Jetstream™ and Jetstream™ GV-X filters are not interchangeable.
Filters should not be modified to fit different blower units.
The user is advised to leave the contaminated area immediately if:
The Manufacturer's Minimum Design Flow (MMDF) warning buzzer sounds.
Breathing becomes difficult. Dizziness or distress occurs. Any part of the system becomes damaged.
Airflow into the Head-Unit decreases or stops. Contaminant can be smelt or tasted inside the Head-Unit.
Materials that may come into contact with the users skin are not known to cause allergic reactions to the majority of
individuals but in the unlikely event of a reaction, the user should immediately leave the contaminated area, remove the
unit and seek medical advice.
System Overview - Jetstream™
Jetstream™ is a belt mounted powered respirator with a replaceable, disposable high efficiency particle filter system.
Jetstream™ contains an 8hr rechargeable battery pack. Jetstream™ will warn the user when the MMDF of 140 L/min, is
reached. The pleated filter has been developed especially for this unit. It is used to filter the air the user will breathe.
The filter is intended to be disposed of once clogged to the point of triggering the warning signal.