5
Maintenance
General
All rotation points are self-lubricating, these do
not require maintenance. Under extreme condi-
tions (aggressive environment) we recommend
lubricating all rotation points every six months
(or when required).
5.1
Daily
Remove all dirt and obstacles that could prevent
the operation of the door.
5.2
Weekly
Check the drive for leaks.
Check the door for damage.
Check that the door is operating properly.
Monthly
5.3
Check the operation of the engine brake. It
should click audibly when opening and closing
the door.
5.4
Annually
The operation and structural condition of the
door must be checked once per year by a quali-
fied technician. A maintenance contract can be
concluded for the service work. Under extreme
conditions, in consultation with Novoferm, the
checks can be performed more often.
Cleaning the door panel
5.5
The door panel is made of PVC. Do not use any
corrosive substances; only use water, neutral
soap or a special door panel cleaner.
Important!
Annual maintenance that is not carried out
by a qualified service centre using original
parts, will void the warranty. (Please ask
your dealer).
+ IMPORTANT +++ IMPORTANT +++ IMPORTANT +
This installation manual must be handed to the customer and must be kept in a safe place throughout the whole period of use!
6
Wear to parts
In order to keep the door permanently in good
condition, the following parts subject to wear
should be replaced once per four years or every
200,000 door movements, whichever occurs first:
For the NovoSpeed Thermo / S600:
The uninterrupted chain-/ steel-cable system
that provides the required tension to the door
In addition, the rubber seals and the brake
should be replaced after 500,000 door move-
ments.
7
Faults
7.1
Faults you can restore yourself
The door is completely unresponsive.
1.
Check that it is connected to the mains power.
2.
Refer to the error code on the display of
the control. Look up the error code in the
manual of the control to find out what it
signified and whether you can restore the
system. If that is not the case, please provide
the error code to your service centre.
The door no longer closes
1.
Check the connection and adjustment of
the safety photocell (see items 10 and 11 of
section 5).
2.
Has an external control been activated?
(For instance, there may be a metal object
on an induction loop!).
7.2
Faults you CANNOT fix yourself
Have the following information at hand before
you contact your service centre:
The serial number (s/n) as indicated on the
nameplate. The information is located on
one of the columns or on the control cabinet.
The control cabinet has a display that
shows error codes. Please provide this error
code to your service centre.
Tip: This error code you can also found in the
manual of the control cabinet. The error
code can be used to restore simple faults
without assistance.