Pressing the Mode button takes you to Setting mode.
In the menu mode, all key parameters can be changed.
The menu mode is exited automatically after 3 minutes in the case of no activity.
When you switch to menu mode, the current operating state is saved, the dosing time
halted and the control unit stopped.
If relevant parameters have been changed, the control units start up again when the
mode is exited (dosing time starts from the beginning); otherwise the dosing time is
continued.
The following settings can be made in the menu sub-items:

3.1 Stop control unit

Now press the OK button. The control unit jumps back into operating mode. The dosing
pumps are now locked. STOP is shown on the display. No chemicals are added to the
pool water. The measurement of the pH value and the Redox voltage is continued.
Activate the control unit the next time the menu is called. Briefly pressing the OK
button lifts the lock on the dosing pumps. The control unit is again in operating mode.

3.2 Manual control

Manual control enables access to the dosing of the pH and the disinfectant. This function
is particularly suited to the commissioning of the measurement, regulation and dosing
system.
The arrow buttons can be used to select/deselect the manual control of "pH" and
"Disinfection". Pressing the OK button for 2 seconds activates manual control for the
1
Menu/menu
cancellation
OK
2
Arrow buttons
3
Selection
3
36