4.5 Making the connections

The following fig. 4 shows all possible connections.
Detailed information can be found in chapters 4.5.1 to
4.5.12.
max. 4 keypad controllers
strobelight, 12 V ,
max. 250 mA*
siren, 12 V ,
max. 500 mA*
anti-tamper contact for
siren + strobelight
programmable
control output*
(internal) speaker mini-
mum impedance 16Ω
12 V operating voltage
for external units*
anti-tamper contacts for
all alarm sensors
alarm zone 1
for NC contacts
alarm zone 2
for NC contacts
alarm zone 3
for NC contacts
alarm zone 4
for NC contacts
key switch or
alarm zone 5
alarm zone 6
for NC contacts
alarm zone 7
for NC contacts
alarm zone 8
for NC contacts
*The current rating of all consumers connected
must not exceed a total of 1 A!
230 V connection
mains fuse T125mA
Fig. 4
Overview of the connections
Hints
1.
All alarm contacts shown in fig. 4 are opening con-
tacts (also called NC contact = normally closed) as
for the majority of the standard components.
Generally it is also possible to use closing con-
tacts (NO contacts = normally open). As an exam-
12 V rech. batt.
T 2A
from the
former
phase (brown)
earthed conductor (green/yellow)
[not required]
neutral conductor (blue)
ple of connection a raid detector is indicated in
chapter 4.5.7. Within a loop, only use one contact
type.
2.
For activating or deactivated the alarm control
system via a key switch, the alarm zone "AZ5"
must be reserved for this purpose.
3.
Please always exactly observe the installation
instructions of the components used.

4.5.1 Speaker

Connect the supplied speaker or another 16 Ω speaker
mains
to the contacts "+ SPKR -" of the terminal strip TB4 (6).
trans-

4.5.2 Alarm unit or individual strobelight and siren

For visual and acoustical alarm either connect an
alarm unit consisting of a strobelight and a siren or
connect these components as individual units to the
terminal strip TB3 (5):
strobelight, 12V , max. 250mA
TB3
+
+
Strobe
Bell
Fig. 5
Connection of an alarm unit
WARNING Most alarm units and sirens produce a
very high sound level. Alarm devices
with a rechargeable battery (independ-
ent power supply) immediately respond
when the rechargeable battery is con-
nected. Therefore, in any case put on a
hearing protection before connecting it.
Important!
The current rating of these consumers and that of the
contacts "PGM1" and "AUX 12V" of the terminal strip
TB4 (6) must not exceed a total of 1 A!

4.5.3 Opening sensors for windows and doors

Reed contacts are used for alarm triggering when
opening a window or a door. These consist of an open-
ing contact which is normally closed by a magnet.
When opening e. g. a door, the magnet withdraws from
the contact so that the contact will be opened. The
alarm loop will be interrupted and the control system
will trigger alarm.
Fig. 6 shows the connection of opening sensors on
the next page.
siren, 12V , max. 500mA
anti-tamper contact
Remove this jumper when
Bell
SAB
connecting an anti-tamper contact!
Hold
TMP
GB
25