8. Technical data

Power supply (AC or DC)
DC supply for all units:
24 V DC ± 10%, at the terminals 11 (-) and 10 (+).
An external DC voltage supply must meet the SELV requirements.
For this supply voltage the unit is classified in protection class 3.
Current consumption max. 70 mA.
According to the type label AC voltage ± 10% at the terminals 15 (L1) and 16
(N), frequency range 50 ... 60 Hz.
For this supply the unit is classified in protection class 2 except for the
terminal blocks. The protective low voltage generated within the unit for the
monitor supply and pulse pick-up supply meets the SELV criteria according to
overvoltage category 2 and soiling degree 2.
Power consumption max. 5 VA.
Inputs
Terminals 2 and 5 for pnp switching 24 V DC pulse pick-ups.
Current consumption: approx. 10 mA.
Switch point for pnp pulse pick-ups: ≥ 14 V ON;< 7 V OFF
The maximum input frequency to be detected is 700 Hz (corresponds to
42,000 pulses/min).
Pulse pick-up supply
Voltage: typ. 24 V DC; current rating: max. 30 mA, protected against short cir-
cuit and overload.
For external DC supply of the unit via the terminals 10 and 11 the supply volt-
age of the pulse pick-up corresponds to the DC supply voltage, less a low
voltage for the short-circuit protection.
For external supply of the unit via the terminals 15 and 16 the supply voltage
of the pulse pick-up corresponds to the rectified non-stabilised output DC vol-
tage of the internal transformer (nominal 24 V).