Technical data
Order no.
Operating voltage
Current consumption max.
Analogue output
Output function
Load impedance
Short-circuit protection
Reverse polarity / overload protection
Angular range (α)
Zero error
Operating temperature
Protection
Housing material
Connection
Dimensions
41
EC2082
20...30 V DC
< 35 mA
current output 4...20 mA DC
I
= 12 mA + sin (α) x 8 mA
a
200...400 Ω (to signal ground at the output)
to U
and to ground
B
• / •
± 90°
< ± 7°
(the zero error can be reduced by ± 4°
by adjustment of the unit)
-30...+85°C
IP 67, II
plastic (Nyrol, PPE)
M12 connector; 4-pole; 0.2 m cable