Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Ec2082; I A = 12 Ma + Sin (Α) X 8 Ma 200 - IFM Electronic EC2082 Montage- Und Installationshinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Contents

Technical data

Dimensions
Mounting
Electrical connection
Characteristics of the output function
Maintenance, repair and disposal
Declaration of conformity
Technical data
Order no.
Operating voltage
Current consumption max.
Analogue output
Output function
Load impedance
Short-circuit protection
Reverse polarity / overload protection
Angular range (α)
Zero error
Operating temperature
Protection
Housing material
Connection
Dimensions
41

EC2082

20...30 V DC
< 35 mA
current output 4...20 mA DC
I
= 12 mA + sin (α) x 8 mA
a
200...400 Ω (to signal ground at the output)
to U
and to ground
B
• / •
± 90°
< ± 7°
(the zero error can be reduced by ± 4°
by adjustment of the unit)
-30...+85°C
IP 67, II
plastic (Nyrol, PPE)
M12 connector; 4-pole; 0.2 m cable
52
EC2082
INCLINATION SENSOR