Herunterladen Inhalt Inhalt Diese Seite drucken

Setting - IFM Electronic ecomot200 S200 Bedienungsanleitung

Schlupf-/gleichlaufwachter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Setting

5.1. Setting of the switching function
Selection is done with switch (4), there are 4 functions:
• Function I:
Preferable for synchronous monitoring, normally open
(relay is energised for synchronous monitoring)
• Function II:
Preferable for slip monitoring, normally closed
(relay is de-energised for slip monitoring)
• Function III:
Slip monitoring, normally open
• Function IV:
Synchronous monitoring, normally closed
Overview of the switching functions
function
I
II
III
IV
relay energised
5.2. Setting of the sensitivity
Selection is done with switch (3), there are 2 functions:
• Switch position I
Slip signal is given when ...
input 1
input 2
• Switch position III → sensitivity setting 7/8
Slip signal is given when ...
input 1
input 2
5.3. Setting of the cycle time
Set the cycle time with pot. (2).
Slip signal is given when the set pulse difference is reached within the set cycle
time (calculation of the cycle time see 5.4)
All manuals and user guides at all-guides.com
start-up delay
synchronous monitoring
relay de-energised
→ sensitivity setting 3/4
receives 3 pulses more than input 2 or when
receives 4 pulses more than input 1.
receives 7 pulses more than input 2 or when
receives 8 pulses more than input 1.
slip monitoring
Page 19

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis