Spezifikationen
port {port_num} w atchdog pinginterval set {num} sets port w atchdog ping interval
port {port_num} w atchdog pinginterval show
port {port_num} w atchdog pingretries set {num} sets port w atchdog ping retries
port {port_num} w atchdog pingretries show
port {port_num} w atchdog retrybooting set
{OFF=0|ON=1}
port {port_num} w atchdog retrybooting show
port {port_num} w atchdog bootretries set {num} sets port w atchdog retry boot timeout
port {port_num} w atchdog bootretries show
radius
radius {PRIMARY=0|SECONDARY=1} enabled set
<off=0/on=1>
radius {PRIMARY=0|SECONDARY=1} enabled
show
radius {PRIMARY=0|SECONDARY=1} server set
"<dns_name>"
radius {PRIMARY=0|SECONDARY=1} server
show
radius {PRIMARY=0|SECONDARY=1} passw ord
set "{passw d}"
radius {PRIMARY=0|SECONDARY=1} passw ord
hash set "{passw d}"
radius {PRIMARY=0|SECONDARY=1} auth timeout
set {num_secs}
radius {PRIMARY=0|SECONDARY=1} auth timeout
show
radius {PRIMARY=0|SECONDARY=1} retries set
{0..99}
radius {PRIMARY=0|SECONDARY=1} retries
show
radius chap enabled set <off=0/on=1>
radius chap enabled show
radius message auth set <off=0/on=1>
radius message auth show
radius default timeout set {num_secs}
radius default timeout show
snmp
snmp port set {ip_port}
snmp port show
snmp snmpget enabled set {OFF=0|ON=1}
snmp snmpget enabled show
snmp snmpset enabled set {OFF=0|ON=1}
snmp snmpset enabled show
snmp snmpv2 enabled set {OFF=0|ON=1}
snmp snmpv2 enabled show
snmp snmpv2 public set "{text}"
snmp snmpv2 public show
snmp snmpv2 private set "{text}"
snmp snmpv2 private show
snmp system {CONTACT=0|NAME=1|
LOCATION=2} set "{text}"
snmp system {CONTACT=0|NAME=1|
LOCATION=2} show
snmp snmpv3 enabled set {OFF=0|ON=1}
snmp snmpv3 enabled show
snmp snmpv3 username set "{text}"
snmp snmpv3 username show
snmp snmpv3 authalg set {NONE=0|MD5=1|
SHA1=2|SHA256=3|SHA384=4|SHA512=5}
snmp snmpv3 authalg show
snmp snmpv3 privalg set {NONE=0|DES=1|
3DES=2|AES128=3|AES192=4|AES256=5|
97
Expert Power Control 1202/1292
show s port w atchdog ping interval
show s port w atchdog ping retries
sets port w atchdog retry booting to on/off
show s port w atchdog retry booting state
how s port w atchdog retry boot timeout
enters cmd group "radius"
enables radius client
show if radius client enabled
sets radius server address
show s radius server address
sets radius server shared secret
sets radius server crypted shared secret
sets server request timeout
show s server request timeout
sets server number of retries
show s server number of retries
enables CHAP
show s if CHAP is enabled
enables request message authentication
show s if request message authentication is
enabled
sets default session timeout (w hen not returned
as Session-Timout Attribute)
show s default session timeout
enters cmd group "snmp"
sets SNMP UDP port
show s SNMP UDP port
enables SNMP GET cmds on/off
show if SNMP GET cmds are enabled
enables SNMP SET cmds on/off
show if SNMP SET cmds are enabled
enables SNMP v2 on/off
show if SNMP v2 is enabled
enables SNMP v3 on/off
show if SNMP v3 isenabled
sets SNMP v2 public cummnity
show s SNMP v2 public community
sets sysLocation/sysName/sysContact
gets sysLocation/sysName/sysContact
sets SNMP v2 private community
show s SNMP v2 private community
sets SNMP v3 username
show s SNMP v3 username
sets SNMP v3 authentication
show SNMP v3 authentication algorithm
sets SNMP v3 privacy algorithm
© 2022 GUDE Systems GmbH