Herunterladen Inhalt Inhalt Diese Seite drucken

Information About The Battery - Sebson GS536GC Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für GS536GC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Explanation of the LED modes :
LED flashes every 32 seconds:
LED flashes every second and alarm sounds:
LED flashes every 32 seconds and a short
alarm tone sounds:
Installation (Fig.8) :
1: Dowel
2. Mounting base
3. Holes for screws for fixing
4: Screw
5: Retainer of the bayonet connection
Attention:
Before drilling the mounting holes, make sure that there are no gas, electricity or water pipes at the
drilling location that could be damaged by this!
Since smoke rises to the top and spreads horizontally, install the smoke detector in the middle of the room if possible.
Observe a minimum distance of 0.5m from the side wall and 0.6m from the corner of the room, as well as a maximum
installation height of 6m (see Fig.6).
Remove the mounting plate located on the back of the housing by turning it counterclockwise.
Select an easily accessible installation location, as the smoke alarm detector must be checked weekly for
proper functioning!
Hold the mounting base to the position on the ceiling where you want to attach the unit. Then draw the holes
for the drill holes on the ceiling with a pencil.
Then drill two holes (Ø 6mm). Take the two plugs included in the delivery and insert them into the drilled
holes.
Screw the mounting base to the ceiling. The screws are included in the delivery.
Attach the housing to the mounting base by turning it clockwise until it clicks into place.

Information about the battery:

This smoke detector is powered by a 9V block battery which is included in the delivery. Under normal conditions the
battery has a lifetime of approx. 5 years. When the battery is running low, a short warning tone sounds every 40
seconds for about 30 days and the LED flashes briefly. During this time the smoke alarm is still fully functional.
However, it is strongly recommended to replace the battery immediately! After approx. 30 days the device is no longer
functional and switches off. Note: Replace the device after an operating period of 10 years!
Reasons for a false alarm:
Water and kitchen vapours
very high air humidity
very dusty air
very heavy smoke from cigarettes or cigars, for example
The smoke alarm detector is working properly..
TEST button is pressed or the alarm has been triggered by
smoke.
Battery is low.
14