Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Levelling Of The Appliance; Circulation Of Ducted Air; Electrical Connection - Palazzetti Royal Rondine Air Serie Installations- Und Wartungsanleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 96
7

INSTALLATION

7.1

Levelling of the appliance

The appliance must be levelled with the help of a
spirit level, by regulating the adjustable feet (Fig.
19).
A = Spirit level.
A

7.2 Circulation of ducted air

The stove is designed for ductable rear hot air
connection.
In order to connect the stove to a ducted heating
system, the rear fan (A) must be connected to a
pipe with diameter 80 mm (B) on one side and
the air distribution vent (C) on the other. Secure
with a hose clamp with diameter of 80 mm.
When the stove is used to heat two or more
adjacent rooms, it is essential to encourage
recirculation of the ambient air to uniform the
temperature in the various rooms.
For air ducting, preferably use smooth,
internally insulated pipes.

7.3 Electrical connection

Simply connect the appliance to the electrical
system using the supplied plug (Fig. 20).
The electrical connection (plug) must be easily
accessible after appliance installation as well.
56
If the power supply cable is damaged
it must be replaced by the technical
assistance service or a qualified techni-
cian in order to prevent any risk.
It is mandatory that the system is
equipped with an earth connection
and a differential switch in compliance
with the laws in force.
The flue gas evacuation duct must
be equipped with its own earth
connection.
Fig. 19

7.4 Fuel optimisation

Excellent fuel depends on different factors (type
of installation, operating and maintenance con-
ditions, type of pellets, etc.)
Upon first ignition, the stove can be regulated for
best combustion performance.
Generally speaking, if at the end of combustion,
there is a lot of residue in the burn pot, you
should change the combustion configuration
(by increasing the value) until you find the best
solution.
Refer to the "Fuel" function in the use and func-
tionality manual. First ignition
The first ignition must be carried out
by the installer.
Fig. 20
004778620 - 23/11/2020

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis