Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
Shower hoses are only suitable for a connection
from the shower to the fitting. Never fit a shut-off
device between the fitting and the hose.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• Optimal functioning is only guaranteed with the com-
bination of Hansgrohe hand showers and Hansgrohe
shower hoses.
• If the Secuflex-Box is installed improperly or not alt all,
the warranty will become invalid.
4
English
Technical Data
Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
Symbol description
Assembly see page 32
Do not use silicone containing acetic acid!
Operation (see page 37)
Dimensions (see page 31)
Flow diagram
(see page 31)
Maintenance check valve (see
page 39)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Cleaning
see enclosed brochure
Cleaning Secuflex hose (see
page 38)
Repeat cleaning when pull out becomes
difficult.
Spare parts (see page 40)
max. 0,6 MPa
0,1 - 0,4 MPa
max. 60°C
max. 70°C / 4 min