PROBLEM
The error message
„E2" will be
displayed.
The error message
„E3" will be
displayed.
The error message
„E4" will be
displayed.
VIII. TECHNICAL DATA
Cooling capacity (Btu/h)/(W)
Capacity of dehumidification (l/h)
Electric input at cooling
Air power (m
/h)
3
Voltage / frequency (V/Hz)
Noisiness (dB(A))
Energy Efficiency Ratio (EER)
Potential of global warming (kg CO
Class of EER
Weight (kg)
Dimensions (WxDxH); mm
Coolant
Maximum quantity of coolant
Discharge Side Pressure
Suction Side Pressure
Effective for a room with a volume of about
Current fuse
Electric input in standby mode
Appliance with protection class
The manufacturer reserves the right to change the technical specifications and
accessories for the respective models.
CAUSE
The room temperature sensor
failed or is damaged.
The sensor of the pipeline of the
vaporizer failed or is damaged.
The container for condensate is
full.
)
2
If repair is necessary, please
contact automatized service.
If repair is necessary, please
contact automatized service.
Drain water from the container.
If this message appears
frequently even if the container
is not evidently full, contact the
service center.
7000 Btu/h/2000 W
0,8 l/h
750 W/3,4 A
220 m
/h
3
220V-240V~ / 50Hz
L
≤54 db(A)
PA
L
≤65 db(A)
WA
2,6
3
A
19,5 kg
unit 310 x 310 x 640 mm
package 370 x 370 x 850 mm
R290
135 g
2,5 Mpa
1,2 Mpa
10-20 m
2
3,15A 250 V
< 0,50 W
I.
32 / 66
SOLUTION