Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 56
GB
IV. INSTRUCTIONS FOR USE
Once connected to mains, the appliance is switched-over to Standby mode (an
acoustic signal will ring out). To actuate the appliance, press the ON/OFF button B1/
C1 - the appliance will switch-on in Automatic mode to a low speed of air blowing, and
corresponding icons on the panel will light up. The display at the same time will display
actual room temperature. Now it is possible to change modes and functions by means of
corresponding buttons, see below. To finish whatever function and switch-off the appliance,
press repeatedly the ON/OFF button B1/C1.

1) BASIC MODE

You may change a mode by pressing the button B3/C3; the modes are changed as follows:
A) Automatic mode ( ) automatically evaluates and determines Cooling or Ventilation
mode depending on actual room temperature.
If room temperature is 24 °C or higher, Cooling mode is activated. If it is lower than 24 °C,
Ventilation mode is activated.
B) Cooling mode (
) decreases room temperature; and warm air is exhausted by the
hose D1 out of the room.
If room temperature is higher than the set temperature, the compressor is activated and
the appliance will start refrigerate. If room temperature is lower than the set temperature,
the compressor is switched-off and only the upper ventilator will remain to be active with
the set speed.
You may set temperature by pressing the buttons B5/C5 and B6/C6 (+,-); the adjusted
temperature (15 - 31 °C) is blinking on for a while on the display B7. After a while, the
temperature inside the room will be displayed. To change the set temperature, use again
the buttons B5/C5 and B6/C6.
C) Dehumidification mode (
) decreases relative humidity in the room. The upper
ventilator is active with the low speed in this mode. The bottom ventilator and the
compressor will switch-off after 8 minutes, and they will be activated again after 6 minutes.
Neither speed nor temperature may be changed.
D) Ventilation mode (
) represents a function of a classic table-top ventilator in
dependence on the set speed. The compressor and the bottom ventilator are not active.
It is not possible to set temperature in this mode.
2) BLOWING SPEED
There are 2 speeds of air blowing (low
- high
), which you may switch-over in the
functions AUTO, cooling or ventilation by pressing the button B2/C2. The respective setting
is signalized on the display by a corresponding icon.
28 / 66

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis