3. OPERATION AND USE

3.1. Operation
3.1.1. General
The outdoor motion detector is ready to use approximately one minute after connecting the power supply (warm-up time). If the
outdoor motion detector is ready to use, the lighting is switched OFF.
3.1.2. Automatic ON
The integrated light sensor continuously measures the ambient light in the detection zone and compares this level with the
preset value specified using the LUX button. The light sensor automatically switches the lighting ON only when the detector
detects motion within the detection range and when the daylight level drops below the preset lux value. The lighting remains
ON as long as motion is detected.

3.1.3. Automatic OFF

The lighting is automatically switched OFF when the preset daylight level is reached.
The integrated timer is used to adjust the delayed OFF time interval as desired. The lighting will remain ON for the duration of
the switch-off delay after the last motion is detected. As soon as the switch-off delay has elapsed, the lighting switches off.
3.1.4. Manual activation
The lighting can also be manually activated by pressing the 230 Vac N.C. push button.
Press and hold the button for more than four seconds to switch the lighting ON, regardless of the measured daylight level.
3.2 Settings
At delivery, the light sensitivity, switch-off delay and detection range are set as follows (factory settings):
light sensitivity
switch-off delay
detection range
These values can be adjusted using the potentiometers under the cover as follows (fig. 4):
light sensitivity
switch-off delay
detection range
To adjust the settings for the lux value, the switch-off delay and light sensitivity open the cover and turn the potentiometers to
the desired position using a screwdriver.
EN
± 50 lux
± 5 mins
Anthracite: 11 m at a height of 2.5 m
White: 14 m at a height of 2.5 m
The METER potentiometer is set to its maximum
5 lux
to infinity
(regardless of daylight level)
test, 1 min – 30 mins
Anthracite: 6, 8 or 11 m
White: 6, 8 or 14 m
17