Electrical Work

Electrical Connections

1. Turn off power.
Turn off power at the circuit breaker or remove fuses to the appliance branch circuit.
2. Connect the power cord.
Connect the power cord in accordance with all governing codes and ordinances.
■ Single-phase connection (220-240 V ~ 50 Hz)
Connect the wires in accordance with the instructions given in the following
table and diagram:
Electrical cable
KY-B925GL
KY-B915AL / KY-B915AB
■ Three-phase connection (380-415 V 3N~ 50 Hz / 380-415 V 2N~ 50 Hz)
Separate the L wires and connect them in accordance with the instructions
given in the following table and diagram:
Electrical cable
KY-B925GL
KY-B915AL / KY-B915AB
50
EN-
Wire connection
: Yellow / Green
(Connect to the earth terminal)
N
N: Black, Cord No. 2 / 4 / 6
L: Black, Cord No. 1 / 3 / 5
L
(Connect to the live terminal)
: Yellow / Green
(Connect to the earth terminal)
N: Grey and Blue together
N
L: Black and Brown together
L
(Connect to the live terminal)
Wire connection
: Yellow / Green
(Connect to the earth terminal)
N
N: Black, Cord No. 2 / 4 / 6
L1: Black, Cord No. 1
L1
L2: Black, Cord No. 3
L2
L3: Black, Cord No. 5
L3
(Connect to the live terminal)
: Yellow / Green
(Connect to the earth terminal)
N
N: Grey and Blue together
L1: Black
L1
L2: Brown
L2
(Connect to the live terminal)