Herunterladen Inhalt Inhalt Diese Seite drucken

IFM Electronic efector180 IX5010 Bedienungsanleitung Seite 28

Elektronischer ventilhubsensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• To monitor the seal the open and closed zones in the mode A are
only 1.5mm. The zones open+seat and closed+seat are immediate-
ly adjacent. In these zones the outputs "open" and "seat" are
switched simultaneously and the outputs "closed" and "seat" are
switched simultaneously. This signals wear of the valve seal!
• In the mode A only 2 valve positions are to be adjusted, the posi-
tions closed and open. The adjustment of the seat lift must not be
carried out, please skip this program step by pressing the Pos. but-
ton. The sensor then automatically generates the mode A.
Error messages
LED
close
Taught position values are not within
the detection range or positions are
Flashes at 8Hz = target is at the edge
close
target is in non defined zones (white
close
Contrary to the other error messages
States of the outputs in case of a fault
28
All manuals and user guides at all-guides.com
Error description
Flashes at 8Hz directly after
leaving the programming mode
= adjustment error!
not permissible or plausible
or outside the detection range or
zones, see above diagram)
for longer than 20s
Flashes at 8Hz
= fault in the electronics.
this error message cannot be
acknowledged or terminated.
Measure
Error message can be
acknowledged by
pressing the
position button
Check the position
of the valve
Replace the sensor
all outputs open

Werbung