Electrical Installation

Electrical installation and servicing should only be carried out by qualified service personnel
and in accordance with all local/national codes of practice and standards e.g. EN 60079-
14:2014 and IEC 60079-14:2013.
Due to the large variations of possible configurations, this manual only covers the standard
installation of the units.
For detailed connection and configuration of units, the installer should refer to individual
project specific drawings and information.
Units can be supplied, as required, with either 24VAC, 110VAC or 230VAC Supply; all ±10%
The units should only be powered from the specified voltage, no allowance is made for
varying voltage supply.
Warning :
3.4.1
Electrical Installation XP & XT Integrated Pan, Tilt, housing assembly
1.
Always use colour-coded conductors or other identification of conductors for ease
of wiring and identification of function at a later date.
2.
Keep a wiring diagram with the system for later use and reference.
3.
Provision is made for one cable entry, at the base mount of the pan tilt.(Fig 14)
To maintain the certification requirements of the unit all cables/conduits must be
fitted at the entry, with certified Ex d Flameproof, compound filled barrier glands,
either brass, nickel plated or stainless steel.
4.
The cable entry to the unit is M25 x1.5 ISO thread, or M20 using an Exd certified
reducer, dependent on what was specified at order.
5.
A minimum of 10 mm depth of engagement must be maintained for all glands.
6.
All glands/reducers must be ingress protected to IP67 or better, to maintain the
weatherproof rating of the equipment.
7.
For maintenance purposes, consult separately supplied additional wiring drawings
specific to the purchase order, for as built wiring and connection details of the unit.
© 2018, Eaton
Installation & Maintenance Instructions
Irreparable damage to the unit will result from the application of
incorrect Power Supply Voltage
IMI+70-XF-XC-XP-XT Issue 8
Page 13 of 43