3.4

Electrical Installation

Electrical installation and servicing should only be carried out by qualified service personnel
and in accordance with all local/national codes of practice and.
Due to the large variations of possible configurations, this manual only covers the standard
installation of the units.
For detailed connection and configuration of units, the installer should refer to individual
project specific drawings and information.
Units can be supplied, as required, with either 24VAC, 110VAC or 230VAC Supply; all ±10%
The units should only be powered from the specified voltage, no allowance is made for
varying voltage supply.
Warning :
3.4.1
Electrical Installation SP & ST Integrated Pan, Tilt, housing assembly
1.
Always use colour-coded conductors or other identification of conductors for ease
of wiring and identification of function at a later date.
2.
Keep a wiring diagram with the system for later use and reference.
3.
Provision is made for two cable entries, at the base mount of the pan tilt.(Fig 14)
4.
The cable entries to the unit are M20 x1.5 ISO thread.
5.
All glands/reducers must be ingress protected to IP67 or better, to maintain the
weatherproof rating of the equipment.
6.
For maintenance purposes, consult separately supplied additional wiring drawings
specific to the purchase order, for as built wiring and connection details of the unit.
© 2018, EATON
Installation Instructions
Irreparable damage to the unit will result from the application of
incorrect Power Supply Voltage
IM-SF-SC-SP-ST Issue 4