Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation Xf & Xc Series Units - Eaton 2400-Serie Installationsanleitung

Feuerfeste kameragehäuse und schwenk- und neigeeinheiten
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EATON
3.4.3
Electrical Installation XF & XC Series units
1. Cable entry type to the housing is via 1 x M20 x 1.5 ISO entry at the side adaptor of the
housing, or for some version via the triple M20 cable entry end cover on the rear of the
housing, solely for connection of power and signal wiring, no internal user wiring is
allowed in this unit.(Fig 15, 16 & 17)
2. Keep a wiring diagram with the system for later use and reference.
3. For maintenance purposes, consult separately supplied additional wiring drawings
specific to the purchase order, for as built wiring and connection details of the unit.
Fig.15 Removing the Wiper Arm
Fig.16 Removing the Front Window flange
© 2018, Eaton
Installation & Maintenance Instructions
To gain access to the internal camera rail,
first the rail will need to be slid out to allow
connections to be made.
If a wiper is fitted, first take note of the
parked position of the wiper arm and then
remove it by loosening the M4 cap head
screw that clamps to the wiper shaft. Keep
the wiper and nylon washer safe for refitting.
This is best done without the sunshield fitted.
IMI+70-XF-XC-XP-XT Issue 8
Remove the front window flange by
first removing the 5 x M6 screws
and then carefully extracting the
flange.
Next slide out the camera
mounting rail, if required.
Page 15 of 43

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1400-serieXp-serieXt-serieXc-serieXf-serie

Inhaltsverzeichnis