F F i i n n e e a a d d j j u u s s t t m m e e n n t t o o f f t t h h e e t t o o o o l l d d i i a a m m e e t t e e r r
N N O O T T E E
D D a a m m a a g g e e t t o o t t h h e e c c u u t t t t i i n n g g e e d d g g e e s s ! !
The cutting edges can be damaged by approaching improperly.
Never approach inserts in the cutting direction with the measuring probe of
the dial gauge.
Setting the diameter
Setting the tool diameter
R R E E S S U U L L T T
The indexable inserts have been completely changed and the tool diameter
has been set. The tool is ready for use.
Montage- und Betriebsanleitung
Montage- und Betriebsanleitung
Installation and Operating Instructions
Installation and Operating Instructions
Position the measuring probe at the
highest point of the adjustment bars
and set the dial gauge to zero.
Approach the highest point of the in-
dexable insert with the measuring
probe. To do this turn the tool opposite
the cutting direction.
I I N N F F O O R R M M A A T T I I O O N N
The required setting dimension for
the tool diameter can be found on
the tool or in the tool drawing.
Turn the adjusting screw clockwise with
a suitable hex-wrench until the appro-
priate tool diameter is reached.
Repeat this step until all the inserts of
this level have been adjusted.
I I N N F F O O R R M M A A T T I I O O N N
The radial run-out of all inserts
after adjustment must be < < 3 3 µ µ m m .