Product information
2.5

Tech data

Dimensions and specifications
Pressure drop diagram
General description
Tilt height
Minimum room height for anode replacement
Connection size, DHW
Connection size, cold water
Connection size, circulation
Inside diameter of test point, solar cylinder
temperature sensor
Inner diameter, test point, cylinder temperature
sensor
Inside diameter of handhole cover
Cylinder capacity
Useful capacity (overall)
Useful capacity (excl. solar thermal heating)
1)
Usable DHW volume
with DHW outlet temperature
45 °C
40 °C
Standby heat loss (24 h) in accordance with
3)
DIN 4753 Part 8
Maximum flow rate at cold water inlet
Maximum DHW temperature
Maximum operating pressure, potable water
Maximum DHW test pressure

heat exchanger

Content
Surface area
Rating code N
according to DIN 4708
L
Continuous output (at 80 °C flow temperature, 45 °C
DHW outlet temperature and 10 °C
cold water temperature)
Heating water volumetric flow rate
Heat-up time at rated output
5)
Maximum heat input
Maximum heating water temperature
Maximum operating pressure of heating water
Connection size, heating water
Heat exchanger (solar)
Content
Surface area
Maximum heating water temperature
Maximum operating pressure of heating water
Connection size, solar
1) Without solar thermal heating or recharging; set cylinder temperature 60 °C.
2) Mixed water at draw-off point (at 10 °C cold water temperature).
3) Distribution losses outside the DHW cylinder are not taken into account.
4) The rating code N
=1 according to DIN 4708 for 3.5 persons, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, DHW outlet temperature 45 °C and cold
L
water 10 °C. Measured at max. heat output. If the heat output is reduced, N
5) In the case of heat generators with a higher heating capacity, limit to the stated value.
Table 5 Tech data
50
Unit
WS 290-5 EPK WS 300-5 PK WS 400-5 EPK/
-
-
mm
mm
DN
DN
DN
mm
mm
mm
l
l
2)
:
l
l
kWh/24 h
L/min
°C
bar
(positive)
bar
(positive)
l
2
m
4)
N
L
kW
l/min
l/h
min
kW
°C
bar
(positive)
DN
l
2
m
°C
bar
(positive)
DN
becomes smaller.
L
WS 400-5 EKP
 Fig. 3/ 4, page 66/ 67
 Fig. 5- 7, page 68/ 69
1935
1640
2100
1850
R1"
R1"
R1"
R1"
R¾ "
R¾ "
19.5
19.5
19.5
19.5
120
120
290
290
120
125
171
179
200
208
2.2
1.9
29
29
95
95
10
10
10
10
5.7
5.8
0.9
0.9
1.7
1.7
28
28.5
11.5
11.7
2600
2600
27
25
28
28.5
160
160
16
16
R1"
R1"
8.6
8.6
1.3
1.3
160
160
16
16
R1"
R1"
W 300-5 PK W 400-5 PK/
W 400-5 KP
1955
1640
2100
1850
R1"
R1"
R1"
R1"
R¾ "
R¾ "
19.5
-
19.5
19.5
120
120
371 | 367
294
155
-
221
429
258
500
2.4 | 1.8
1.8
37
30
95
95
10
10
10
10
6.9
8.6
1.0
1.3
2.8
9
27
42
11.7
17
2600
3500
34
39
27
42
160
160
16
16
R1"
R1"
12.0
-
1.8
-
160
-
16
-
R1"
-
Stora – 6720821526 (2021/06)
1955
2100
R1"
R1"
R¾ "
-
19.5
120
375
-
536
625
2.1 | 1.7
38
95
10
10
12.0
1.8
13
54.5
22.3
3500
41
54.5
160
16
R1"
-
-
-
-
-