UNIT INSTALLATION
6.3.5 Power and transmission wiring connection

Safety instructions
?
N O T E
Check the requirements and recommendations in the chapter
TRICAL AND CONTROL SETTINGS"
!
D A N G E R
Do not connect the power supply to the indoor unit prior to filling
the space heating circuit (and DHW circuit if it were the case)
with water and checking water pressure and the total absence of
any water leakage.
Do not connect or adjust any wiring or connections unless the
main power switch is OFF.
When using more than one power source, check and ensure that
all of them are turned OFF before operating the indoor unit.
Avoid wiring installation in contact with the refrigerant pipes,
water pipes, edges of plates and electrical components inside
the unit to prevent damage, which may cause electric shock or
short circuit.
!
C A U T I O N
Use a dedicated power circuit for the indoor unit. Do not use a power
circuit shared with the outdoor unit or any other appliance.
Make sure that all wiring and protection devices are properly selected,
connected, identified and fixed to the correspond ing terminals of
the unit, specially the protection (earth) and power wiring, taking
into account the applicable national and local regulations. Establish
proper earthing; Incomplete earthing may cause electrical shock.
Protect the indoor unit against the entry of small animals (like rodents)
which could damage the drain pipe and any internal wire or any other
electrical part, leading to electric shock or short-circuit.
Keep a distance between each wiring terminal and attach insulation
tape or sleeve as shown in the figure.
Tape or sleeve
23
PMML0336B rev.1 - 03/2016
All manuals and user guides at all-guides.com

Access to the electrical box before performing the next steps:
1 Using the appropriate cable, connect the power circuit to the
"5 ELEC-
2 Connect the transmission wires between outdoor and indoor
3 Carry out the necessary electrical connections of the optional
4 Pass the electrical wiring from the TB1 and TB2 to the lateral
Connection procedure
appropriate terminals as shown on the wiring label and the
illustration below. Connect the power supply cables to the
terminal board (TB1) , and the earth conductor to the earth
screw in the electrical box plate.
TERMINAL BOARD 1 (TB1)
Power terminals
Power terminals
Case 1. Power supply:
1~ 230V 50Hz
unit to the terminals 1 and 2 on the terminal board 2 (TB2).
Indoor unit
1
2
Outdoor unit
1
2
accessories using the terminal board 2 (TB2). Consult its
label for a better understanding.
?
N O T E
Refer to the section
"5.5 Optional indoor unit wiring
holes of the electrical box. Then, fix the cables to the cord
bands located at the right side. Finally, take the cables out
through the bottom side of the unit.
Earth terminal
Case 2. Power supply:
3N~ 400V 50Hz
(accessories)".