7. Withdrawing and inserting the device

(10)
(2)
Fig. 5
Insert the withdrawing handles (2) into the openings (11) until
they snap into place. Withdraw the front part together with
the main PCB out of the housing.
To reassemble the unit, insert the front part together with the
main PCB into the housing until the swallow-tailed sections
engage in each other.
8. Mounting
The SINEAX SV 824 can be mounted either on a top-hat rail
or directly onto a wall or mounting plate.
When deciding where to install the transmitter
(measuring location), take care that the limits of
the operating temperature are kept:
– 20 and + 55 °C!
8.1 Top-hat rail mounting
Simply clip the device onto the top-hat rail (EN 50 022) (see
Fig. 6).
Fig. 6. Mounting on top-hat rails 35 × 15 or 35 × 7.5 mm.
All manuals and user guides at all-guides.com
ON
ON
(
(

8.2 Wall mounting

Drill 2 holes of approx. 4.5 mm diameter in the wall or panel
as shown in the drilling pattern (Fig. 7).
Fig. 7. Drilling pattern.
The wile pressing the latch (17) in the base of the device
(Fig. 8, left), pull out the amplifier securing brackets.
Now secure the instrument to the wall or panel using two
4 mm diameter screws.
(9)
(15)
(16)
(15)
(17)
(9)
Fig. 8. Rear of device.
(9)
Screw hole brackets
(15) Top-hat rail clips
(16) Rubber buffers
(17) Latch for pulling the screw hole brackets out
(18) Latch for pushing the screw hole brackets in
Note:
To return the brackets to their original positions, the latch (18)
in de base of the devices has to be depressed before
applying pressure to the securing brackets (9) (see Fig. 8,
right).
(9)
(18)
(9)