To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Important!
Do not dismantle the thermoelement only replace it cpl.
Check the non return valves, clean, renew if necessary
and lubricate with special valve grease.
Reassemble in reverse order.
Adjust unit.
In the event of frost hazard and draining the pies, the
installation unit must be removed.
If the hot water and cold water connection are exchaned,
turn the installation unit 180° around.
Technical data
Minimum flow pressure with
downstream resistance
Max. operating pressure
Recommended operating pressure
Test pressure
Max. hot water temperature
Temperature scale adjustible
Safety check
Hot water connection
Cold water connection
Nominal capacity for ½" and ¾" by 3 bar 66 l/min
Adjustment function from min. flow rate 13 l/min
Temperaturbegrenzung for example max. 42° C
1
4
Adjustment (please see page 4)
English
The water temperature at the hot water inlet should be
at least 2° C higher then the desired hot water
temperature.
The Hansgrohe ½" thermostatic mixer (code number
15373180) and ¾" (code number 15374180), can
be used in conjunction with hydraulic or thermostatically
controlled combination boilers providing there is a
minimum of 1,5 bar pressure and the combinaton boiler
prepare enough water for the downstream consumption.

Spare parts

1
2
3
4
5
6
0,1 bar
7
10,0 bar
8
1,0 - 5,0 bar
16,0 bar
XXX = Colors
80° C
000 chrome plated
20° - 80° C
090 chrome plated/gold
38° C
810 satinox
LH
880 satin chrome
RH
2
for example 42° C
Setting knop
Cover plate
Sleeve
Thermoelement
Non return valve
Seals
Seals
Extension 40 mm
3
36391XXX
95028XXX
96635XXX
96633000
96644000
96636000
96364000
92615000
5