6. FAQ
Battery
Is it okay not to use them for a long time
Does charging affect the battery life after
Usage
If the tool housing is used continuously in
conventional riveting mode (D) for a certain
period of time, will the heating in the tool
housing affect normal use?
7. Troubleshooting
Malfunction
The battery is plugged into the charger and
the green light is on
During
charging
Red light is on while the battery is charging
All displays on the function panel blink
The indicator light flashes once within a
certain period of time and switches off
after 15 seconds.
The indicator light flashes within a certain
period of time and switches off after 15
The indicator light flashes 4 times within
a certain period of time and switches off
after 15 seconds.
The indicator light flashes 5 times within
a certain period of time and switches off
after 15 seconds.
failed rivet setting process
U
S
A
Rivet not pulled out or pulled out of
G
E
Loose rivets after rivet installation
If the above method does not remedy the situation, the riveting tool must be repaired by professional personnel or the tools must be returned to the seller or manu-
Questions
each use
seconds.
fastening
Charge the battery every 6 months, otherwise it may deteriorate in performance after 6
Suggestion: When the remaining battery is only 25% (a light on the display) or when the battery
is exhausted, it should be recharged to increase the battery life.
As the high-speed motor causes the gear to rotate, the heat generated during the riveting pro-
cess is transferred to the outside, which does not affect the normal use of the tool. The user is
advised to wear suitable protective gloves.
Probable cause
Battery malfunction or damage, error, char-
ging not possible.
Abnormal charging temperature (battery over-
heating) outside normal range (0°C~45°C)
Low power alarm
Motor short-circuit alarm
Overheating alarm on the control panel
Engine blockage alarm
Switch on in case of failure or unusually high
power demand.
Battery damaged
Loose clamping jaws
Battery capacity exhausted,
check power indicator
The jaws are worn, the nosepiece is dirty, the
jaw sleeve or the nosepiece hole is deformed.
Incorrect selection of the working tensile
forces
The remaining rivet mandrel is stuck in
the jaw piece group or the remaining rivet
mandrel is blocked in the chuck housing or in
the feed-through tube
The rivet mandrel collector is full
The mouthpiece was incorrectly chosen
Incorrect selection of the stroke
The selection of the rivet does not match the
workpiece hole
facturer for repair!
Answers
months.
Correction of defects
Stop charging immediately, remove the
battery and replace it with a new battery.
Immediately switch off the power, remo-
ve the battery and check the charger
Remove the battery
Please send the battery to qualified,
professional maintenance personnel for
inspection and repair. If in doubt, please
contact the authorised dealer in good
time for advice and repair.
New batteries must be replaced
Assembly of the clamping jaws
Charge (see P9 Battery check) or replace
the battery if necessary
Replace the jaws, tighten the nosepiece,
remove impurities and replace the jaw
sleeve or the nosepiece
Set the working clamping force correctly
(see P10)
Remove the broken rivet and the setting
jaws for clean lubrication; Take out
the broken rivet and remove residues
/ debris
Gauging the full mandrel collector
Choosing the right nosepiece
Adjust the stroke correctly
Choose the right nosepiece, or replace it
with a new one