Herunterladen Inhalt Inhalt Diese Seite drucken

Sharp VC-G20SM Serviceanleitung Seite 20

Video cassette recorder
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

VC-G20SM/G200SM
VC-G201SM/G401SM
3 Next, press the tracking button (+), (–) and change
the ATR signal waveform from max to min and from
min to max. At this time adjust the height of supply
and take-up side guide roller with the adjustment
driver (JiGDRiVERH-4) so that the ATR signal wave-
form changes nearly parallel.
4 If the tape is lifted or sunk from the helical lead
surface, the PB ATR signal waveform appears as
shown in Figure 4-30.
5 Press the tracking button (+), (–) and make sure that
the ATR signal waveform changes nearly parallel.
6 Finally, check tape crease near the reverse guide. If
tape crease is found, adjust tilt screw 45˚ counter
clockwise. Small tape crcase will appear at retain
guide after this adjustment finished.
Adjustment
3 Move the A/C head with the X value adjustment gear
driver by the method shown in Figure 4-28, and
adjust the A/C head so as to get the maximum ATR
signal waveform. (Note: At this time adjust so as to
get the maximum ATR signal waveform nearest the
A/C head position which has been set in case of X
value rough adjustment as stated in 4-17, 3- 2.)
4 Adjust the playback switching point (Refer to the
electric adjustment method.)
5 Playback the self-picture-recorded tape, and check
the flatness of ATR signal waveform and sound.
When the tape is above the helical lead.
Supply side
Supply side guide roller
Take-up side guide roller
rotated in clockwise
rotated in clockwise
direction (lowers guide
direction (lowers guide
roller) to flatten
roller) to flatten
ATR signal.
ATR signal.
Figure 4-30.
PB ATR
Signal
Head switching pulse
4. A/C head X value adjustment
1 Fix A/C head arm screws 1 by the method described
in 4-15 "Replacement 3".
2 Playback the alignment tape (VROUBZFS), and
shortcircuit between TP801 and TP802. As a result
the auto-tracking is automatically cancelled, so that
the X value adjustment mode is set.
When the tape is below the helical lead.
Take-up side
Supply side
Supply side guide roller
rotated in counterclock-
wise direction (raises
guide roller) to make the
tape float above the helical
lead. The supply
side guide roller is then
rotated in the clockwise
direction to flatten the
ATR signal.
Notes:
When the A/C head X value adjustment is performed, be
sure to perform at first X value rough adjustment (refer to 4-
17, 3-2).
1
20
Figure 4-29.
Take-up side
Take-up side guide roller
rotated in counterclock-
wise direction (raises
guide roller) to make the
tape float above the
helical lead. The take-up
side guide roller is then
rotated in the clockwise
direction to flatten the
ATR signal.
Figure 4-31.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vc-g200smVc-g201smVc-g401sm

Inhaltsverzeichnis