Type__PROP
•
(only if set to Timed there are two new entries to make dosage cycles ON /
OFF selectable)
Timed ON
o
Timed OFF
o
Chlorine_Measure
Setpoint___1.2_ppm
•
possible to adjust from 0.0 to 5.0 ppm
sp_type___low
•
ofa_time_000_min
•
AlrBand__1.0ppm
•
Type__PROP
•
(only if set to Timed there are two new entries to make dosage cycles ON /
OFF selectable)
Timed ON
o
Timed OFF
o
Flow rate meas.
sensor_K Factor
•
key) It's possible to select K Factor of W. Meter (Water Meter). Once the
type of sensor will be changed the system will ask for a reset of the
resettable totalizer and a new start date for the counter.
K factor___1.00
•
type of sensor selected in the menu item before) For K Factor sensor:
Adjust value from 0.01 to 99999,99. For W. Meter sensor the value is in
pulses/liter; adjust value between I=0÷999 L=0÷999. If the sensor is
calibrated in this menu (K Factor and Water Meter), the string "Cal" appear
for a couple of seconds in place of the actual number, indicating that the
instrument will use the parameter recalculated based on the calibration.
Flow unit___L/s
•
(L/s), liters per minute (L/m), cubic meters per hour (m
minute (GPM))
Total unit___L
•
3
meters (m
) and gallons (GAL))
Reset tr total
•
message, "ENTER to confirm", will be asked to set the new start date for the
counter (dd/mmm/yyyy). If there is not date set in the screen with the Tr
totalizer value will be displayed "install".
INPUT Flow
(Adjust value with enter and up or down key Enable or Disable)
•
It's possible to enable(ON) or disable (OFF) signal input
Cal
(Calibration_probe) (Adjust value with enter and up or down key)
§
§
§
3 PUMP*
(Third external pump management) It's possible to enable (ON) or
disable (OFF) the output for external pump
§
§
(Adjust value between OFF, PROP, ON/OFF or TIMED)
(Change the value from 5 to 3600 seconds)
(Change the value from 5 to 3600 seconds)
(only if enabled)
(Adjust value with enter and up or down key) It's
(Adjust value LOW or HIGH)
(Change the value from 1 to 240 minutes or Off)
(Adjust value from 0.0 to 5.0 ppm)
(Adjust value between OFF, PROP, ON/OFF or TIMED)
(Change the value from 5 to 3600 seconds)
(Change the value from 5 to 3600 seconds)
(only if is present)
(Select the sensor type with enter and up or down
/
W.Meter__1
(Change the measure unit between: liters per second
(Change the measure unit between: liters (L), cubic
(Reset the resettable totalizer) After a confirmation
Full
(pH 7 and 4, Redox 465 mV buffer solution)
Easy
(pH 7, Redox 465 mV buffer solution)
Off
(Disabled)
3P-TIME ON
(Adjust value from
the time which the third external pump output is
3P-TIME OFF
(Adjust value from
the time which the third external pump output is off)
rev. 6.1
I
/ 1L
(This screen depend from the
3
/h) and gallons per
00m01s to
00m01s to
59m59s, it's
active)
59m59s, it's
3