3.4.3 CHECKWEIGHER MODE
Long press
to enter setting, press
When done, press
Press
to confirm the upper limit value and move to the next level setting, that is to choose the type of alarm mode.
Choose 0/1/2, and press
right side of the panel.
When entering the upper and lower limit values, the
selects the digits to the left.
Alarm mode selection:
0 Turn off alarm
1 Alarm sounds when the weight is within upper and lower limits
3 Alarm sounds when the weight is outside upper and lower limits.
To come back to normal mode, press and hold

4. AUTOMATIC SLEEP TIME SETTING

The scale goes into sleep mode to save battery when the scale is idle for a minute or as set in this function. After entering the sleep mode,
any weight placed on the scale will cannot wake up the indicator. The scale can only be woken up by pressing any keys or cycling the power.
In the weighing mode, press
into the time setting mode. Select a value between 0-99min using the same method as described in Alarm mode digit setting. Press
confirm the value. Now FA SLP will be be displayed again. Press

5. CALIBRATION

Turn on the scale and the selftest will start, before it change into the weighing situation, press
P 0000.
Set the password P 2222,and press
CHANGE THE DIVISION:
Press the key
until display shows F1-DIV, Press
press
for confirm.
CHANGE THE DECIMA LOCATION:
Press the key
until display shows F2-pnt ,Press
then press
for confirm.
CHANGE THE MAX CAPACITY:
Press the key
then press
for confirm.
CALIBRATE
to select the F4-CAL , then press
Press the key
capacity value can be changed ) and this number keeps flashing, put on 50kg weight, press
50.000, take away the weight from the platform, display shows 0.0000, power off the scale, then turn on the scale again, if display shows
0.000, the calibration is finished
repeatedly until 4 alar is displayed. Press
to enter upper limit value.
to confirm. Now you have entered the Alarm mode. The mode is confirmed by function indicator light on the
and
at the same time, then by pressing
,it will show F1 DIV.
until display shows F3-CAP , Press
increases the digit value, and the
, 1Off will be displayed. Press
to get back to normal mode.
to go into the menu, and press the
to go into the menu, and press the
to go into the menu, and press the
to show CAL-1. Then press
OPTIMA USERS GUIDE
to enter the place to input the lower limit value.
selects the digits to the right, and
and the scale will return to normal mode.
repeatedly, select FA SLP and press
three times. Until display shows
key to change the division value, then
key to change the decimal location,
key to change the max capacity,
,when display shows50.000 (the max
key make it stop flashing, display shows
EN
EN
to enter
to
13