PSI 6xCx.762xx | R911173895
Bosch Rexroth AG | Electric Drives and Controls
77/90
Features
7.1.18 The input "Transformer Temperature"
The input "Transformer Temperature" is checked only in a sequence from
beginning of the squeeze time until the end of the hold time.
7.1.19 Serial inputs 8.00 - 11.15
Here, the operator can store up to 4 different 16 Bit values. The Weld Controller
will read-in these values at the end of the Weld Time and will store them at a
protocol memory for the latest spot. An external data entry device can readout
these data periodically and store them.
The Weld Controller will not evaluate these values or change them.
(Take care of the order)