Mounting LUC-T10, LUC-T20
6.3.3
Mounting with mounting
bracket or adapter flange
10
Mounting with mounting bracket
(for version with parallel thread only)
Mounting with adapter flange
(parallel thread)
oooooo
LUC-Z
Process connection
F73 DN 50 PN 16
F93 DN 80 PN 16
FA3 DN 100 PN 16
Sensor connection
G5 G 1½ ISO 228
G6 G 2 ISO 228
Material
S 1.4435 (AISI 316L)
P PPs (polypropylene)
400 (15.6)
G
A
• G1½: A = 55 mm (2.1 in)
Order No.: LUC-Z13
• G2: A = 66 mm (2.6 in)
Order No.: LUC-Z14
• Material: 1.4301 (AISI 304)
adapter flange
Mounting with adapter flange
(conical thread)
oooooo
LUC-Z
Process connection
A61 ANSI 2", 150 psi
A81 ANSI 3", 150 psi
A91 ANSI 4", 150 psi
Sensor connection
N5 1½ - 11.5 NPT
N6 2 - 11.5 NPT
Material
S 1.4435 (AISI 316L)
P PPs (polypropylene)
sensor
120 (4.7)
ø16 (ø0.6)
3.0 (0.12)
sealing ring
supplied
nozzle