INDEX

1. Specifications

2. Dimension
3. Installation and connection
4. Accessories
5. Electrical Wiring
6. Display Controller Operation
7. Troubleshooting
8. Exploded Diagram
9. Maintenance
10. WIFI function- 'Alsavo Pro' APP operation
Thank you for using INVERBOOST swimming pool heat pump for your pool heating, it will heat your pool water and
keep the constant temperature when the air ambient temperature is at -12 to 43℃
ATTENTION: This manual includes all the necessary information with the use and the installation of your
heat pump.
The installer must read the manual and attentively follow the instructions in implementation and maintenance.
The installer is responsible for the installation of the product and should follow all the instructions of the
manufacturer and the regulations in application. Incorrect installation against the manual implies the exclusion of
the entire guarantee.
The manufacturer declines any responsibility for the damage caused with the people, objects and of the errors due
to the installation that disobey the manual guideline. Any use that is without conformity at the origin of its
manufacturing will be regarded as dangerous.
WARNING: Please always empty the water in heat pump during winter time or when the ambient temperature
drops below 0℃, or else the Titanium exchanger will be damaged because of being frozen, in such case, your
warranty will be lost.
WARNING: Please always cut the power supply if you want to open the cabinet to reach inside the heat pump,
because there is high voltage electricity inside.
WARNING: Please well keep the display controller in a dry area, or well close the insulation cover to protect the
display controller from being damaged by humidity.
WARNING: The heat pump must be stored and transported vertically in the original packaging.If this is not the case,
it cannot be operated immediately. A minimum time of 24 hours is required before power on.
- Please always keep the heat pump in the ventilation place and away from anything which could cause fire.
- Don't weld the pipe if there is refrigerant inside machine. Please keep the machine out of the confined space
when make gas filling.
- Action of filling gas must be conducted by professional with R32 operating license.