1 hour later
Filtration pump will start
to run for 5 mins to
detect the water in
temp.
Note: If the water volume of the swimming pool is small, water temp reaches T1≥Tset+1℃ and last for 5
mins, heat pump will stop first and then filtration pump stops, but it will not entry standby mode for 1 hour.
If water temp drops to T1≤Tset-1, heat pump will start again.
2. While P3=1: When the heat pump is on (running or standby), filtration pump will always be on.
NOTE :
Tset = Tseting water temperature
For example : Tset = 28℃ Tseting water temperature in your pool heat pump
Tset-1 = less 1℃ than Tseting temperature
Tset- 1 = 28-1=27℃
Tset+1= more 1℃ than Tseting temperature
Tset+ 1 = 28+1=29℃
Example
Condition
Tset=28℃
T1>Tset-1℃
T1>27℃
T1≤Tset-1℃
T1≤27℃
T1<Tset+1℃
T1<29℃
T1≥Tset+1℃
T1≥29℃
Water pump working logic
Filtration pump will enter standby mode for another
1 hours and will not start except after turning off
the hp and restart.
Heat pump will start again until it meets the
condition of standby.
Filtration pump will enter standby mode for another
1 hours and will not start except after turning off
the hp and restart.
Heat pump will start again until it meets the
condition of standby.