08 - CLEANING, CARE AND MAINTENANCE
Storage
Before you store the device, make sure that the gasvalve is completly closed and the pressure regulator
disconnected from the gastank. Only put the protection hood on, when device has cooled.
Cleaning
Clean coated surfaces with a soft, damp cloth. Never clean the heater with flammable or caustic clea-
ning agents. Make sure that the burner is cleaned regularly. Insects can get caught in the burner hou-
sing and burn during operation.
Maintenance
Perform a leak test after a longer period of non-use. If there is any damage to the technology, do not use
the device and contact customer service.
09 - TECHNICAL DETAILS
Construction properties
• Transportable patio and garden heater with
tank housing
• Housing made of steel with powder coating or
stainless steel
• Gas hose connections with metal clamp
• Heat emission reflector
Table of the injector
Gas category
3+ (28 - 30/37)
Gas-Types
Butane
Gas pressure
28 - 30 mbar
Total heat input:
13 kW (Butan: 945 g/h • Propan 928 g/h)
(HS): (QN)
Injector Size
1.88 mm to Main burner
0.18 mm to Pilot burner
The mark on the injector (e.g. 1.88) indicates that the size of the injector is 1.88 mm
Technical properties
• Only use propane or butane gas
• Max. Wattage: 13 kW
• Min Wattage: 5 kW
3B/P(30)
LPG
Propane
Gasmixture
37 mbar
29 mbar
1.55 mm to Main burner
0.18 mm to Pilot burner
3 B/P (50)
3B/P(37)
LPG
LPG
Gasmixture
Gasmixture
50 mbar
37 mbar
1.65 mm to Main burner
0.18 mm to Pilot burner
EN
69