05 - GASLEAK TESTING

The gas connections are tested for tightness in the factory before delivery. A complete leak test
must be carried out at the installation site after installation.
During the test, no heat and fire sources can be present in the vicinity of the device!
1. Mix a soap solution of one part liquid cleaner and one part water. The soap solution can be applied
with a spray bottle, brush or cloth. In case of a leak, soap bubbles will form.
2. The heater must be checked with a full gas bottle.
3. Make sure that the regulator is set to OFF.
4. Turn the gas supply completely on.

06 - CONTROL

Igniter
Piezo ignition generates
sparks in the burner when
pressed.
Important:
Insert battery
before start-
up. The entire
ignition knob
can be turned
up counterc-
lockwise,
underneath
is the battery
compartment
for the ignition.
OFF: The heating turns off
LO: Minimum temperature
HI: Maximum temperature
Gas supply completely
interrupted. No flame in
the burner.
Regler
Drehen, um die Flamme zu
regulieren. Drücken, um die
Gaszufuhr zu öffnen (Pilot).
Off
Pilot
Gas supply only when
regulator is pressed.
High
Maximum gas supply.
Strong flame in the
burner.
Low
Minimal gas supply.
Weak flame in the
burner.