Electrical Wiring
The wiring for the power line of the indoor unit, the wiring between indoor and outdoor units, and the wiring between
indoor units:
Items
Total Current of
Indoor Units(A)
<10
≥10 and <15
≥15 and <22
≥22 and <27
• The electrical power line and signal lines must be fastened tightly.
• Every indoor unit must have a ground connection.
• The power line should be enlarged if it exceeds the permissible length.
• Shielded lays of all the indoor and outdoor units should be connected together, with the shielded lay at the side of the
signal lines of the outdoor units grounded at one point.
• The whole length of the signal line should not exceed 1000m.
Signal Wiring of Wired controller
Length of Signal Line (m)
≤ 250
• The shielding lay of the signal line must be grounded at one end.
• The total length of the signal line should not be more than 250m.
Dipswitch Setting
Indoor Units PCB
In the following table, 1 represents ON and 0 represents OFF.
Definition principles of code switches:
SW01 is used to set capabilities of master and slave indoor units as well as indoor unit; SW03 is used to set indoor unit
address (combine original communication address and address of centralized controller).
(A) Definition and description of SW01
SW01_1
SW01_2
Address of wire
SW01_3
controlled indoor unit
SW01_4
SW01_5
SW01_6
Capability of indoor unit
SW01_7
SW01_8
Cross
Length (m) Rated Current
Section
of Overflow
(mm2
Breaker(A
2
20
20
3.5
25
30
5.5
30
40
10
40
50
Wiring Dimensions
0.75mm2 × core shielding line
[1]
[2]
[3]
0
0
0
0
0
0
0
0
0
1
0
1
∙∙∙
∙∙∙
∙∙∙
1
1
[5]
[6]
[7]
0
0
0
0
0
0
0
0
Rated Current of Residual Circuit
Breaker(A) Ground Fault Interrupt-
er(mA) Response time(S)
20 A,30 mA,0.1S or below
30 A,30 mA,0.1S or below
40 A,30 mA,0.1S or below
50 A,30 mA,0.1S or below
[4]
Address of wire controlled indoor unit (group address)
0
0
0# (wire controlled master unit) (default)
0
1
1
0
1
1
0
0
0
1
∙∙∙
1
1
[8]
0
0
0
1
1
0
1
1
19
Cross Sectional
Area of Signal Line
Outdoor -indoor
(mm2)
2 cores×0.75-2.0mm2
shielded line
1# (wire controlled slave unit)
2# (wire controlled slave unit)
3# (wire controlled slave unit)
4# (wire controlled slave unit)
5# (wire controlled slave unit)
∙∙∙
15# (wire controlled slave unit)
Capability of indoor unit
0.6HP (AB05)
0.8HP (AB07)
1.0HP (AB09)
1.2HP (AB12)
Indoor -indoor
(mm2)