Herunterladen Diese Seite drucken

Safety Notes; Installation Instructions; Technical Data; Symbol Description - HANSGROHE ShowerSelect 15762003 Gebrauchsanleitung, Montageanleitung

Vorschau ausblenden Andere Handbücher für ShowerSelect 15762003:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from
using this product.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• If the thermostat or mixer is set to maximum water
temperature, there is a risk of scalding at hydraulical
opening of the check valve. For this reason,
Hansgrohe recommends that you set up the "Safety
Function".

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking
water!

Symbol description

Do not use silicone containing acetic acid!
Safety Function (see page 14)
The desired maximum temperature for example max.
42º C can be pre-set thanks to the safety function.
Adjustment (see page 14)
After the installation, the output temperature of the
thermostat must be checked. A correction is necessary if
the temperature measured at the output differs from the
temperature set on the thermostat.
2
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
English
Maintenance (see page 16)
• The check valves must be checked regularly
according to EN 806-5 in accordance with national
or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Dimensions (see page 18)
Flow diagram (see page 18)
free flow
Spare parts (see page 20)
+
Special accessories (see page 20)
order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep
enough)#13597000, #13593000
• levelling set 1° #95521000
Cleaning (see page 18)
Operation (see page 19)

Werbung

loading

Diese Anleitung auch für:

Showerselect s 15744003