SWITCH-MODE BATTERY CHARGER

GENERAL INFORMATION

The CB516
-3
switch-mode battery charger has
been expressly designed for the caravanning and
boating sector and can automatically charge 12V
lead batteries, with different charging values
according to the position set using the selector
positioned inside.
6 phase automatic charging system
Phase 1: Desulphation -
battery charger, only if need
is charged at 15.2V
exceeds 2A or for a maximum of 2 hours.
Phase 2: Bulk - battery charging with maximum
current until the end-
reached.
Note: the end-
reached only if the battery is efficient.
Phase 3: Absorption - battery charging at costant
end-
of-
charge voltage for the time defined
by the charging line with a progressive
current reduction until the charging is
completed.
The position of the selector must be set according
to the
most suitable charg
type of battery installed.
I
n most cases, the selector can be set
for led-
acid
batteries,
batteries and
on
position C for AGM batteries.
Nevertheless, it is recommended to consult the data
sheet of the battery installed.
when
switching on the
ed the battery
,
until the current
of-
charge voltage is
of-
charge voltage is
,
ing
voltages for the
on
position A
on
position B for le d-gel
« »
a
« »
Selector on position "A"
Selector on position "B"
Selector on position "C"
Threshold
T he battery charger is protected against
overtemperature and the 12V
protected against short circuit and polarity inversion.
The high frequency switching technology allows
high performances with small dimensions and
limited weight.
Phase 4: Float - Maintenance charg
voltage for a maximum time of 15 hours. A
h
igh
again.
Phase 5: Stand-by - The battery charger stops
supplying power. It will switch over to the
Refresh phase only when the battery
voltage goes under 13
Phase 6: Refresh
voltage for a maximum time of 1h; this
phase
battery self-discharge. Once completed,
the
phase.
« »
DESULPHATION
BULK
1
2
15,2V
Max 14,1V
15,2V
Max 14,4V
15,2V
Max 14,7V
Max 2h
outputs are
ing
load
lead to phase
s
V
.
- The battery is charged at the
is
designed to compensate for
charging
starts again from the
ABSORPTION
FLOAT
STAND-BY
3
4
1,5h
13,5V
0A
13,8V
8h
0A
3h
13,8V
0A
V< 13,0V
Max 15h
EN
at constant
Bulk
starting
Bulk
the
Float
REFRESH
5
6
14,1V
14,4V
14,7V
7
Max 1h