LOOP DETECTOR
Operating instructions for installation and commissioning
1
Safety instructions
These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended operating voltages and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.
Mounting and electrical connection
2
SMA is mounted directly onto a standardized 35-mm mounting rail.
The terminals for all connections are coded pluggable terminals.
The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please wire the device in accordance with the terminal assignment. Make sure the terminals are assigned correctly.
Loop connection
Supply voltage
1-channel device
+/~
A1
–/~
A2
3
Value and parameter setting options
General
The settings of the devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be made using
the corresponding method.
3.1
LCD display and controls
Standard display
Standard display
1-loop device
2-loop device
1
1
2
Basic functions 0 (see Table 4.1a for settings)
3.2
Parameters
1: Door and gate
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
2: Barrier
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
3: Quiescent current The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.
4: Direction logic
Output 1 switches if an object moves from loop 1 to 2. Output 2 switches if an object moves from loop 1 to 2. Both loops must be
activated for a short time. The outputs are reset again when loop 2 returns to a non-activated condition. Both loops must have re-
turned to a non-activated condition for another direction detection.
0: Loop 2
Loop 2 / output 2 can be deactivated in a 2-loop device.
Relay response to malfunctions (see chapter 6 Troubleshooting):
A malfunction causes
1.Door/gate
the output relay to be
released. The alarm
systems
relay drops out.
SMA - SMA 2 - SMA 230
Loop connection
2-channel device
L3
1
L3
L4
L4
L5
2
L6
Control button
Control button
Mode
Data
Sim1
Sim2
A malfunction causes
the output relay to pick
2. Barrier
up. The alarm relay
drops out.
Alerting
common
31
11
nc
12
32
34
14
no
Explanation of the LCD display
Loop 1, output 1
Function
Loop 2,
output 2
1
2
Example:
Example:
Time
Parameter «h»
function set
set
A malfunction causes the
3. Quiescent
output relay to be
released. The alarm relay
current
drops out.
Documentazione
Tecnica
T20
rev. 4.0
08/2012
©
CAME
CANCELLI
AUTOMATICI
119RT20-EN
(Translation)
Output
2nd output
common
common
21
nc
nc
22
24
no
no
Explanation of the LED
Info
Red:
Start-up phase
Green:
Operation
Red & green:
Configuration
Flashing green:
Loop activated
Flashing red:
Error
Flashing red + green:
Simulation
A malfunction causes
4. Direction logic
the output relays to be
(2-loop device
released. The alarm
only)
relay drops out.
1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sma 2Sma 230

Inhaltsverzeichnis