Wall Mounting
For assistance in determining wall plate location, see Height Finder at sanus.com.
2-1: Wood Stud Mounting
CAUTION:
Improper use could reduce the holding power of the lag bolt. To avoid potential injuries or property damage:
Pilot holes MUST be drilled to a depth of 89 mm (3.5 in.), using a 5.5 mm (7/32 in.) diameter drill bit.
Do not over-tighten the lag bolts [25].
Any material covering the wall must not exceed 16 mm (5/8 in.).
Minimum wood stud size: common 2 x 4 in. (nominal 1.5 x 3.5 in.)
2-2: Solid Concrete and Concrete Block Mounting
CAUTION:
Improper use could reduce the holding power of the lag bolt. To avoid potential injuries or property damage:
Pilot holes MUST be drilled to a depth of 89 mm (3.5 in.), using a 10 mm (3/8 in.) diameter drill bit.
Be sure the anchors [26] seat fl ush with the concrete surface.
Mount wall plate directly onto the concrete surface.
Never drill into the mortar between blocks.
Do not over-tighten the lag bolts [25].
Minimum solid concrete thickness: 8 in.
Minimum concrete block size: 8 x 8 x 16 in.
Wood Stud Wall Mounting – See Cautions in Step 2.
1.
Locate studs. Verify the center of the stud with an awl or thin nail or use an edge
to edge stud fi nder.
2.
Level the wall plate [01] and mark the hole locations.
3.
Drill pilot holes as illustrated.
4.
Tighten the lag bolts [25] only until the washers [27] are pulled fi rmly against
the wall plate [01].
2
[01]
4
[27]
[25]
(6901-002114 <00>)
CAUTION:
[01]
13 mm
(1/2 in.)
1
< 16 mm
(5/8 in.)
3
89 mm
3.5 in.
2
5.5mm
(7/32 in.)
2-1
41 - 61 cm
(16 - 24 in.)
11