Herunterladen Inhalt Inhalt Diese Seite drucken

TECNOINOX PF 8GG9-Serie Handbuch Seite 12

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
Part 2
To convert the appliance to another type of gas, e.g. from natural gas to
LPG, the nozzles of the main burner, by-pass and pilot light have to be
changed. All the nozzles are marked with a number that indicates the
diameter in 1/100 of a mm and are supplied in a bag.
Connection to the distribution network, installation, and maintenance of the appliance must be carried out by qualified
technicians only, in observance of all applicable regulations!
BURNER:
1.
Pull the knobs off .
2.
Remove the control panel by unscrewing the fixing screws placed
at its lower part.
3.
Replace the nozzle "U" (pic .9) with a suitable one for the new type
of gas indicated in the "MAX" nozzles table T1 section
Specifications.
BURNER:
7.
Pull the knobs off.
8.
Remove the control panel by unscrewing the fixing screws placed
at its lower part. .
9.
Replace the nozzle "U" (pic. 10) with a suitable one for the new
type of gas indicated in the "MAX" nozzles table T1 section
Specifications.
ADJUSTING THE AIR:
10. Loosen the fixing screw "X" (pic .10)
11. Adjust the primary air by moving the bracket "S" (pic. 10) up to the
distance "H" indicated in nozzles table T1section
Specifications.
Screw the fixing screws in.
To replace the nozzle of the oven burner and of the pilot flame and to
adjust the primary air, follow the instructions below:
BURNER:
PF
PFX
1.
Remove the base of the oven "N" (pic. 8)
Unscrew and replace the nozzle with a suitable one for the new
type of gas indicated in the "MAX" nozzles table T1 section
Specifications.
ADJUSTING THE AIR:
2.
Loosen fixing screw "X" (pic .14)
3.
Adjust the primary air by moving the bush up to the distance "H"
(pic. 14) indicated in nozzles table T1 section Specifications
(see pic .14).
4.
Block the bush, by screwing in fixing screw "X" (pic .14)
Cooktop burner, nozzles and air adjustment
Solid top burner (models PP../PFP..)
Oven burner (models GG9)
GB / IE - 3
After each transformation or adaptation, the unit must undergo an
operating test and the supplementary plate must be updated according
to the conversion or adaptation carried out.
ADJUSTING THE AIR:
4.
Loosen the fixing screw "X" (pic .9)
5.
Adjust the primary air by moving the bush up to a distance "H"
indicated in nozzles table T1section Specifications.
6.
Screw the fixing screws in.
PILOT FLAME:
12. Unscrew the closing nut "Z" (pic. 9). .
13. Unscrew and replace the pilot nozzle "D" (pic .9) with a suitable
one for the new type of gas indicated in the nozzles table T1
section Specifications.
14. Replace and tighten the closing nut.
MINIMUM:
15. Unscrew and replace or adjust the minimum by-pass nozzle "Um"
(pic .11) on the basis of the indications in the nozzles table T1
section Specifications.
16. Remove the control panel.
17. Replace the knob.
PILOT FLAME:
5.
Unscrew and remove closing nut "X" (pic .12)
6.
Unscrew and replace pilot nozzle "D" (pic.12) with a suitable one
for the new type of gas indicated in the nozzles table T1 section
Specifications.
7.
Replace and tighten the closing nut "X" (pic .12)
8.
Replace the base of the oven "H" (pic .8)
MINIMUM:
9.
Pull the knobs off.
10. Remove the control panel by unscrewing the fixing screws placed
at its lower part.
11. Unscrew and replace or adjust the minimum by-pass nozzle "Um"
(pic .13) on the basis of the indications in the nozzles table T1
section Specifications.
12. Remove the control panel.
13. Replace the knob
N.B. If the bottom of the oven chamber is removed, it has to be put back
in its proper position.
Transformation and adaptation

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis