Herunterladen Inhalt Inhalt Diese Seite drucken

Visual Fault Locator; Troubleshooting - VOLTCRAFT PM-32 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

13. Visual fault locator

Important
Always replace the protective covers when finished working. This will protect against
accidental discharge from the laser, scratches, dust, and moisture from entering.
Only use standard adapters.
Make sure the components you connect are clean and free of dust.
Use care when attaching and removing connections to prevent scratches.
Make sure you observe the precautions indicated in the section "Safety instructions
→ Laser". This also applies to laser light projections from the fiber optic cable being
tested.
1. Remove the protective cover and connect the fiber optic cable to the laser output port.
2. Press
to turn the power ON.
3. Press the
constant if the laser is on, and blinks if the laser is blinking.
Never look directly into the laser beam and never point it at people or animals. Do not
point the laser beam at mirrors or other reflective surfaces.
4. Press and hold
5. Disconnect the fiber optic cable and replace the protective cover.

14. Troubleshooting

Problem
Display is dim
Meter cannot be turned on
Displayed data is not normal or
garbled
26
button repeatedly to cycle the laser ON → blinking → OFF.
to turn the power off.
Suggestion
Batteries are low, replace the batteries
Replace the batteries
The connector may be faulty or dirty. Clean and
reconnect the cable(s)
Make sure the connections are attached properly.
will be

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2299816

Inhaltsverzeichnis